AUx5, AUx6, AUx7, AUx8
OUTPUT OPTIONS
Option No.
Description
Default
Note
P155e
AUX5 TIMeR
20 sec
1 to 99 seconds
P156e
AUX6 TIMeR
20 sec
1 to 99 seconds
P157e
AUX7 TIMeR
20 sec
1 to 99 seconds
P158e
AUX8 TIMeR
20 sec
1 to 99 seconds
Option No.
Description
Default
Note
P160e
AlARM SIReN VOlUMe
99
1 to 99 levels
P161e
FIRe SIReN VOlUMe
99
1 to 99 levels
P162e
CHIRP SIReN VOlUMe
16
1 to 99 levels
P155e, P156e, P157e, P158e
AUx5 – AUx8 timers
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
20 sec.
relAteD oPtions
P151e 8e Pulse AUX5
P152e 8e Pulse AUX6
P153e 8e Pulse AUX7
P154e 8e Pulse AUX8
Sets the length of pulse time for the AUX5 – AUX8 outputs when the outputs are set for
Pulse mode. Select 1 to 99 seconds.
TO PROGRAM
Press P155e, P156e, P157e or P158e (The existing Pulse Time will be displayed).
Press [NeW TIMe] e (The new Pulse Time will be displayed).
P160e
AlArm siren VolUme
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
level 99 (highest)
Sets the Audible Alarm volume level for the Siren output.
Select volume from 1 (lowest) to 99 (highest).
TO PROGRAM
Press P160e (The existing volume level will be displayed).
Press [NeW leVel] e (The new level will be displayed).
P161e
Fire siren VolUme
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
level 99 (highest)
Sets the Fire Alarm volume level for the Siren output.
Select volume from 1 (lowest) to 99 (highest).
TO PROGRAM
Press P161e (The existing volume level will be displayed).
Press [NeW leVel] e (The new level will be displayed).
P162e
CHirP siren VolUme
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
level 16 (low volume)
Sets the Chirp volume level for the Siren output.
Select volume from 1 (lowest) to 99 (highest).
TO PROGRAM
Press P162e (The existing volume level will be displayed).
Press [NeW leVel] e (The new level will be displayed).
67
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g
Содержание D16xD
Страница 94: ...NOTES ...