system oPerAtion sHortCUts
Some keypad operations can be programmed to operate with or without a User Code.
PROGRAMMING SeQUeNCe:
P62e 1e–6e
toggles the options ON and OFF
1e on: Memory Display shortcut
2e on: Zone exclude shortcut
3e on: Home Mode shortcut
4e on: Keypad Panic shortcut
5e on: area1 arming shortcut
6e on: area2 arming shortcut
oPerATinG exAMPleS:
Arming without shortcut:
[User Code]
Arming with shortcut:
Keypad Panic without shortcut:
[User Code]
Keypad Panic with shortcut:
NOTe:
[User Code]
always triggers Keypad Panic.
KPX lCD KeyPAD, see option P64e 6e to enable Double Key Panic.
STD lCD KeyPAD, see option P126e 1e to enable Double Key Panic.
P62e 1e–6e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
1e, ON: Memory Display shortcut enabled.
2e, ON: Zone exclude shortcut enabled.
3e, ON: Home Mode shortcut enabled.
4e, OFF: Keypad Panic shortcut disabled.
5e, ON: Area1 Arming shortcut enabled.
6e, OFF: Area2 Arming shortcut disabled.
relAteD oPtions
P64e 6e STD lCD keypad double key
panic.
P126e 1e, 2e, 3e KPX keypad double
key keypad functions.
notes
If either Area1 or Area2 are armed by
shortcut and no user codes are assigned to
that Area then it will always remain armed.
you will then need to enter program mode
on power-up and assign codes to Areas.
siren bUrst on AUto exClUDe
This option allows the disabling of the 2 second siren burst at the end of exit Time
which indicates a zone/s has been Auto excluded.
PROGRAMMING SeQUeNCe:
P62e 7e
toggles the option ON and OFF
oFF: Siren burst on auto exclude disabled
on: Siren burst on auto exclude enabled
P62e 7e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Siren burst on Auto exclude
enabled.
relAteD oPtions
P60e 6e Auto exclude zones.
exit time x10
This option multiplies the normal exit time by a factor of 10.
PROGRAMMING SeQUeNCe:
P62e 8e
toggles the option ON and OFF
oFF: exit time is the time set by P28e
on: exit time is multiplied by 10
exAMPle: if P28e = 22 seconds then if P62e 8e is on, the exit time
is 22 x 10 = 220 seconds.
P62e 8e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: exit Time x10 disabled.
relAteD oPtions
P28e exit Time.
Option No.
Description
Default
P62e
1e
Shortcut Memory display
ON
2e
Shortcut Zone exclude
ON
3e
Shortcut Home Mode
ON
4e
Shortcut Keypad Panic
OFF
5e
S hortcut Area1 Arming
ON
6e
Shortcut Area2 Arming
OFF
7e
Brief warning on Auto exclude
ON
8e
exit Time x10
OFF
27
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g
Содержание D16xD
Страница 94: ...NOTES ...
Страница 96: ......