CONNeCTION DIAGRAMS
PCB V8
8
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
RECEIVER
LISTEN
SERIAL
READER
PROG
INTERNAL TAMPER
Heartbeat LED
Keypad Connection (alternative)
KEYPAD
BA
TT
ERY
RED +
AUX1
AUX2
AUX3
AUX4
+12V
0V
TAMP
+12V
+12V
+12V
0V
Z8
C
Z7
Z6
C
Z5
Z4
C
Z2
Z3
C
Z1
0V
CLK
DAT
COM
K
E
Y
PA
D
RESET
STR
SIREN
BLACK
J1 LINK
&
BOX TAMPER PROGRAM LINK
= Sealed, normal state
= Tamper alarm state
Power up with link off to enter
installer program mode
BATTERY LEADS
(supplied)
J1
Main Board Rev8
D8x or D16x
LISTEN
Audio Alerts &
dialler listen-in
diagnostics.
Requires separate
audio amp & spkr
BATTERY CONNECTION
For 12V 7Ah Backup
battery (Ness BAT210)
RECEIVER
Header for
connecting
optional Radio
Interface.
AUX
Aux outputs 1-4
SERIAL
RS232 serial port
READER
Connection for
up to 3 Ness
Weigand
Also used for Ness PD
Portable Download tool.
readers.
TELEPHONE
+
12
V
Z1
6
C
Z1
5
Z1
4
C
Z1
3
Z1
2
C
Z1
0
Z1
1
C
Z9
0V
Up to 2 x Strobe Light (NOI-300)
Up to 3 x Horn Speaker, 8 Ohm (NOI-110)
12V DC output
N.O TAMPER SWITCH
(761-002) Colour: BLACK
Supplied with Ness siren covers
N.C TAMPER SWITCH (SWI920) Colour: WHITE
ALTERNATIVE TAMPER SWITCH WIRING
For N.C. Tamper Switches
Zone 2
Zone 6
Zone 4
Zone 8
Zone 7
Zone 1
Zone 5
Zone 3
12V DC output for detectors.
500mA max.
Auto Reset fuse protected.
from all 12V outputs.
+12V
(Red)
CLK (White)
DAT (Blue)
T
COM (Black)
Polarity is not important for this output
BOX TAMPER SWITCH
(White) N.C. contacts
Connect to J1
1. Listen Out
2. not used
3. Common
4. +12V out
8 ohm spkr
pins 1 & 3
and connection for
output expander/s
Telephone lead (Australia only).
Connect to Mode3 socket.
END OF LINE RESISTORS
The default end of line resistor value is 2k2 (2200 Ohms). The EOL value is fully
programmable with a choice of 13 resistor values, see program option P129E.
Ness panels are supplied with 2k2 1% tolerance Metal Film resistors.
Colour code: Red, Red, Black, Brown, Brown.
NORMALLY OPEN
(
DEVICES
N.O.)
NORMALLY CLOSED
(
DEVICES
N.C.)
ZONE WIRING
Detector
Detector
Zone
C
Zone
C
Up to 3 x 12V Screamer (100-238, 100-004)
KPX keypad
Saturn keypad
navigator keypad*
*navigator keypad is compatible with D8x/D16x control
panels version 7.0 or later
Maximum 3 mixed
keypads or 4 navigator
keypads per system.
ZoneS 9-16
D16x only
Zone
S 1-8 D8x & D16x
17VAC
Plug Pack
Dual voltage power input.
17VAC or 20VDC
to avoid damage please connect the
correct power supply as shown.
17V AC
POWeR SUPPly
20V DC
POWeR SUPPly
yellow/Green
To panel earth (optional)
* Optional power supply.
This power supply has positive and negative
20VDC output however the polarity is not
important in this case.
Part No. 840-054
Part No. 840-029
This power supply is included with most D8x/D16x
models (Australia only).
Non-Polarity
17VAC
20VDC*
Brown
Blue
17VAC or
20VDC
Power InPut
non-PolArIty
17VAC or
20VDC
Power InPut
non-PolArIty
Содержание D16xD