AUx4
OUTPUT OPTIONS
P144e 1e – 8e
enHAnCeD AUx4 oUtPUt oPtions
Available in D8x/D16x V6 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
All off.
notes
Any or all options may be selected on.
The P144e enhanced AUX4 options work along with P124e and AutoTimers to provide
multiple choices of events and alarms to control AUX4.
TO PROGRAM
1. Press
P144e.
2. Press
1e ... 8e
to turn an option on. Multiple options can be selected.
P144e 1e
AreA1 ArmeD to AUx4
Turns on AUX4 while Area 1 is armed.
P144e 2e
AreA2 ArmeD to AUx4
Turns on AUX4 while Area 2 is armed.
P144e 3e
Home ArmeD to AUx4
Turns on AUX4 while armed in Home mode.
P144e 4e
keyPAD toggle AUx4
When this option is on,
AUX4 is turned ON or PUlSeD with the keypress 44* (* = left hand STAR button).
AUX4 is turned OFF with the keypress 44# (# = Right hand STAR button).
P144e 5e
telePHone remote Control oF AUx4
notes
Remote operation by telephone
procedure as detailed in the user and
installation manuals must be followed
before access is allowed. This includes
entering a valid user code.
relAteD oPtions
P90e 5e, enable remote Aux control.
When this option is on,
AUX4 is turned ON or PUlSeD with the telephone keypress 44*
AUX4 is turned OFF with the telephone keypress 44#
FeeDbACk tones HeArD by PHone:
3 BeePS: The AUX has been turned ON or is already ON.
1 BeeP: The AUX has been turned OFF or is already OFF.
1 lONG BeeP: error. Remote AUX operation by telephone is not enabled.
P144e 8e
PUlse AUx4
relAteD oPtions
P148e, AUX4 Pulse Time.
This option converts the P144e 1e, 2e, 3e, 4e, 5e options into a pulsed AUX4 output.
AUX4 is pulsed on for the time set in P148e.
Option No.
Description
Default
Note
P148e
AUX4 TIMeR
20 sec
1 to 99 seconds
P148e
AUx4 timer
Available in D8x/D16x V6 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
20 sec.
relAteD oPtions
P144e 8e
Sets the length of pulse time for the AUX4 output when the P144e 8e option is selected.
Select 1 to 99 seconds.
TO PROGRAM
Press P148e (The existing Pulse Time will be displayed).
Press [NeW TIMe] e (The new Pulse Time will be displayed).
65
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g