oPtion
DeSCRIPTION
DeFAUlt PAge
P62e
1e
Shortcut Memory display
ON
27
2e
Shortcut Zone exclude
ON
3e
Shortcut Home Mode
ON
4e
Shortcut Keypad Panic
OFF
5e
Shortcut Area1 Arming
ON
6e
Shortcut Area2 Arming
OFF
7e
Brief warning on Auto exclude
ON
8e
exit Time x10
OFF
P63e
1e
Home Mode alarms to ReSeT output
ON
28
2e
Home Mode alarms to STROBe
ON
3e
Home Mode alarms to SONAleRT
ON
4e
Home Mode alarms to SIReN
OFF
5e
Day Mode to ReSeT output
ON
6e
Day Mode to STROBe
OFF
7e
Day Mode KP SONAleRT (Chime KPX)
OFF
8e
Day Mode to SIReN
OFF
P64e
1e
Brief Home Mode Alarm
OFF
29, 30
2e
Brief Day Alarm
OFF
3e
Home zones entry Delay2
ON
4e
Radio Key SIReN CHIRPS
OFF
5e
[not used]
ON
6e
Strobe Flash on Home arm by radio
OFF
7e
[not used]
OFF
8e
[not used]
OFF
P65e
Supervised zones
NONe
31
P66e
1e
Zone Supervision alarm to ReSeT o/p
OFF
32, 33
2e
Zone Supervision alarm to STROBe
OFF
3e
Zone Supervision alarm to SONAleRT
OFF
4e
Zone Supervision alarm to SIReN
OFF
5e
enable WIReD ZONe supervision
OFF
6e
[not used]
OFF
7e
Zone Supervision speedup x 6
OFF
8e
Zone Supervision speedup x10
OFF
P67e
Zone Supervision Time
24 (hours)
33
P68e
1e
Double Press Radio Panic
OFF
34
2e
Auto Re-Arm
OFF
3e
long Radio Message
ON
4e
"OK/READy" Display
OFF
5e
Radio Arming “unsealed” warning
OFF
6e
24hr Zone Fire Siren sound
OFF
7e
Single Shot strobe on Arm by R/Key
OFF
8e
Quiet chirps on radio Arm/Disarm
OFF
P69e
1e
Flash strobe on medical alarm
OFF
36, 37
2e
[not used]
OFF
3e
Quiet Home Mode Siren
OFF
4e
6 beeps on Arming
OFF
5e
Home arm by radio key ON/OFF
OFF
6e
Disable Mains Fail Alarm
OFF
7e
exit BeePS - Full Arm
OFF
8e
exit BeePS - Home Mode
OFF
oPtion
DeSCRIPTION
DeFAUlt PAge
P00e
Follow Me Telephone Number.
none
38
P26e
eNTRy DelAy Time 1
20 sec
16
P27e
entry Delay Time 2
6=60 sec
P28e
eXIT DelAy Time
60 sec
P29e
SIReN ReSeT Time
5 min
P30e
Normal Zone Sensitivity
all zones
17
P31e-36e
Vibration Sensitivity, High-low
none
P37e
long Response Zones - 1 second
none
P38e
long Response Zones - 3 seconds
none
P39e
Double Trigger zones
none
18
P40e
Instant zones
zones 3+
P41e
eNTRy DelAy 1 zones
Zone 1
P42e
HANDOVeR zones
Zone 2
19
P43e
entry Delay 2 zones
none
P44e
lockout zones (ReSeT output)
All zones
P45e
AReA 1 zones
All zones
19
P46e
AReA 2 zones
none
P51e
HOMe MODe zones
none
21
* See page 20 for information on Area operation, Home mode &
Temporary Day Zones
20
P52e
24hr zones
none
21
P53e
Day Mode zones
none
P54e
ReSeT output zones
All zones
22
P55e
STROBe zones
All zones
P56e
Keypad Sonalert zones
All zones
P57e
SIReN zones
All zones
23
P58e
Aux1 / Aux3 zones
none
P59e
Aux2 / Aux4 zones
none
P60e
1e
entry Beeps
ON
24, 25
2e
Keyswitch Home Monitor/Disarm
OFF
3e
Keyswitch Arm/Disarm
OFF
4e
Tamper Siren lockout
ON
5e
Duress to ReSeT output
OFF
6e
Auto exclude zones
ON
7e
Auto keypad display off
OFF
8e
Delayed Aux3, Aux4 outputs
OFF
P61e
1e
Tamper to ReSeT output
ON
26
2e
Tamper to STROBe output
ON
3e
Tamper to Keypad Sonalert
ON
4e
Tamper to SIReN output
ON
5e
Keypad Panic to ReSeT output
ON
6e
Keypad Panic to STROBe output
ON
7e
Keypad Panic to Sonalert
ON
8e
Keypad Panic to SIReN output
ON
u
u
u
u
Options marked "u" can be programmed in User Program Mode
All
options can be programmed in Installer Program Mode
u
u
D8x/D16x V8 ProgrAmming oPtions sUmmAry
Page 2 of 6
87
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Содержание D16xD