enAble test CAlls
This option enables the reporting of dialler test calls to the Central station.
PROGRAMMING SeQUeNCe:
P89e 1e
toggles the option ON and OFF
oFF: no test Calls
on: test Calls enabled
P89e 1e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Test Calls enabled.
relAteD oPtions
P83e Test Call Interval.
P84e Time before next Test call.
P87e 4e Number Of Dialling Attempts.
mAins rePort DelAy
This option allows Mains Fail reports to be delayed by one hour if the mains power has
been off continuously for that time. This avoids mains fail reports being sent to the
Central Station in the event of brief power failures.
PROGRAMMING SeQUeNCe:
P89e 2e
toggles the option ON and OFF
oFF: Mains Fail reports immediately
on: Mains Fail report is delayed by 1 hour
P89e 2e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Mains Fail report is delayed.
listen-in to DiAller
This is a diagnostic feature to allow the installer to hear the dialler message and other
telephone tones through a horn speaker.
There are 2 methods of listening to the dialler.
metHoD 1:
Temporarily connect a horn speaker to the lISTeN pins on the main
board. This method required no programming options to be set - the lISTeN pins are
always active.
metHoD 2:
This method requires option P89e 3e to be turned on. listen-In is enabled
for a minimum of 4 minutes after exiting Program Mode.
During Method 2 listen-In, the dialler message and other telephone tones can be
heard through the Siren output (at low volume) while the dialler is sending reports. The
4 minute period is restarted whenever any key on the keypad is pressed.
To turn listen-In off, go back into Installer Program mode and toggle the option OFF.
PROGRAMMING SeQUeNCe:
P89e 3e
toggles the option ON and OFF
oFF: Method 2 Listen-in disabled
on: Method 2 Listen-in enabled
P89e 3e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No listen–In.
notes
Use MeTHOD 1 if you already have the
panel box open and have a spare horn
speaker on hand.
Use MeTHOD 2 if the box is closed and
you need to quickly listen in to the dialler.
Keep in mind that the dialler tones will be
heard via any horn speaker/s connected
to the Siren output.
Option No.
Description
Default
P89e
1e
eNABle TeST CAllS
ON
2e
Mains Report Delay (1 hour)
ON
3e
listen-In to Dialler
OFF
4e
Swinger shutdown
ON
5e
line Fault Monitor
OFF
6e
[not used]
OFF
7e
[not used]
OFF
8e
[not used]
OFF
48
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g