remote ACCess
When selected on, this option allows the panel to be remotely upload/downloaded by a
remote computer or controlled by a remote telephone.
When the option is Off, the panel will not answer incoming telephone calls, preventing
any type of remote access while the panel is in normal Operating Mode.
WHen tHe PAnel is in instAller ProgrAm moDe it Will AnsWer All
inComing CAlls regardless of the P90e 1e setting.
PROGRAMMING SeQUeNCe:
P90e 1e
toggles the option ON and OFF
oFF: no remote access
on: remote access enabled
P90e 1e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Remote Access.
relAteD oPtions
P91e Required Rings.
remote Arming
Allows the control panel to be armed remotely by telephone, using a standard DTMF
telephone or mobile phone.
PROGRAMMING SeQUeNCe:
P90e 3e
toggles the option ON and OFF
oFF: no remote arming
on: remote arming enabled
P90e 3e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Remote Arming.
notes
• Remote Access must also be enabled.
relAteD oPtions
P90e 1e enable Upload/Download.
See page 85 for details on Remote
Operation by telephone.
P90e 2e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Second Call Mode enabled.
notes
If Callback is enabled (P90e 8e is on),
then First Call mode is disabled.
relAteD oPtions
P91e Required Rings.
enAble "First CAll" moDe
For remote access the panel can answer incoming telephone calls on either the First or
Second Call.
First Call mode
: The panel answers a telephone call after the number of rings set by
P91e. Used if the panel has exclusive use of the the telephone line.
second Call mode
: The panel answers on the second telephone call. The first
telephone call must ring for at least the number of rings set by P91e. The second call
to the panel must be made after a wait of between 10 and 50 seconds. Second Call
mode is used to stop other equipment such as fax machines from answering the call.
PROGRAMMING SeQUeNCe:
P90e 2e
toggles the option ON and OFF
oFF: Second Call Mode enabled
on: First Call Mode enabled
Option No.
Description
Default
P90e
1e
enable Remote Access
OFF
2e
enable First Call Mode
OFF
3e
enable Remote Arming
OFF
4e
enable Remote Disarming
OFF
5e
enable Remote AUX control
OFF
6e
enable Remote Status reporting
OFF
7e
enable Remote event Report
OFF
8e
enable Callback Mode
OFF
50
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g