P57e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All ON: All zones trigger Siren output.
notes
•
0e
will turn all selections OFF
MeMory e
will turn all selections ON
siren oUtPUt Zones
Selects the zones to trigger the Siren output.
PROGRAMMING SeQUeNCe:
P57e [Zone no]e
toggles the options ON and OFF
[Zone no] oFF: the zone will not trigger the Siren output
[Zone no] on: the zone will trigger the Siren output
P58e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All OFF: No zones trigger AUX 1 or 3
notes
•
0e
will turn all selections OFF.
MeMory e
will turn all selections ON.
relAteD oPtions
P121e 5e-8e
Day zone output mapping.
AUx1,3 oUtPUt Zones
Selects the zones to trigger the AUX1 or AUX3 outputs. This option selects
which
zones trigger AUX1 or 3.
Use P121e 1e and/or P123e 1e to enable the ouput.
Once turned on by a zone alarm, the output will remain on until the panel is reset/
disarmed.
PROGRAMMING SeQUeNCe:
P58e [Zone no]e
toggles the options ON and OFF
[Zone no] oFF: the zone will not trigger auX1,3 output/s
[Zone no] on: the zone will trigger the auX1,3 output/s
P59e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All OFF: No zones trigger AUX 2 or 4
notes
•
0e
will turn all selections OFF.
MeMory e
will turn all selections ON.
AUx2,4 oUtPUt Zones
Selects the zones to trigger the AUX2 or AUX4 outputs. This option selects
which
zones trigger AUX2 or 4.
Use P122e 1e and/or P124e 1e to enable the ouput.
Once turned on by a zone alarm, the output will remain on until the panel is reset/
disarmed.
PROGRAMMING SeQUeNCe:
P59e [Zone no]e
toggles the options ON and OFF
[Zone no] oFF: the zone will not trigger the auX2,4 output/s
[Zone no] on: the zone will trigger the auX2,4 output/s
23
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g