AUx2
OUTPUT OPTIONS
Any or all of the P142e options may be selected.
Option No.
Description
Default
P142e
1e
Area1 Armed to AUX2
OFF
2e
Area2 Armed to AUX2
OFF
3e
Home Mode arm to AUX2
OFF
4e
Keypad toggle AUX2
OFF
5e
Telephone remote control of AUX2
OFF
6e
[not used]
OFF
7e
[not used]
OFF
8e
Pulse AUX2
OFF
Only one of the P122e options may be selected.
Option No.
Description
Default
P122e
1e
Zone alarms to Aux2
ON
2e
Zone Supervision alarms to Aux2
OFF
3e
Aut R/Key Panic TOGGleS Aux2
OFF
4e
Radio Key AUX button Pulses Aux2
OFF
5e
Phone line fail to Aux2
OFF
6e [not used]
OFF
7e
DOTl alerts to Aux2
OFF
8e
Reader output pulses Aux2
OFF
P122e 1e-8e
AUx2 oUtPUt oPtions
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
1e on.
notes
Only one option can be on. Turning an
option on turns off another.
relAteD oPtions
P142e 1e-8e enhanced AUX2 options.
P354e 7e-8e AutoTimer1 AUX2 options.
P359e 7e-8e AutoTimer2 AUX2 options.
P364e 7e-8e AutoTimer3 AUX2 options.
P369e 7e-8e AutoTimer4 AUX2 options.
P122e is one of several options which control the behaviour of the AUX2 output.
One of the most powerful features of the D8x/D16x panels is the flexibility to control
the AUX outputs by various events and alarms. If the AUX2 output does not behave as
expected, please check all related options such as AutoTimers and P142e options.
TO PROGRAM
1. Press
P122e.
2. Press
1e ... 8e
to turn an option on. Only one option can be on.
P122e 1e
Zone AlArms to AUx2
relAteD oPtions
P59e Aux2 zones.
With this option ON, zones selected in P59e will turn on Aux2 when they go into alarm. The
Aux2 output turns off when the panel is disarmed/reset.
P122e 2e
Zone sUPerVision AlArms to AUx2
relAteD oPtions
P65e, P66e, P67e Radio Supervision.
Setting this option turns the AUX2 output ON when a SUPeRVISeD RADIO alarm is
triggered. The Aux2 output turns off when the panel is disarmed/reset.
P122e 3e
enAble AUx2 For AUtotimer / rADio key AUx toggles AUx2
Available in D8x/D16x V6 and later.
relAteD oPtions
P350e to P369e. AutoTimers 1 to 4.
Dual action programming option.
When this option is on, AUX2 is enabled for use by AutoTimer and Radio Key/s AUX button
will TOGGle the AUX2 output.
P122e 4e
rADio key AUx bUtton PUlse AUx2
relAteD oPtions
P146e AUX2 Timer
When this option is on, Radio Key/s AUX button button will PUlSe the Aux2 output.
P122e 5e
telePHone line FAUlt to AUx2
When this option is enabled, a telephone line fault condition will turn on the Aux2 output.
Aux 2 will turn off when the telephone line is restored.
P122e 7e
Door oPen too long (Dotl) Alerts to AUx2
relAteD oPtions
P303e DOTl zones.
P304e DOTl timer.
This option enables DOTl zones (P303e) to turn on AUX2 when the DOTl Time (P304e)
expires.
P122e 8e
reADer oUtPUt to AUx2
relAteD oPtions
P318e, P328e, P338e, P319e, P329e,
P339e.
This option enables an access control reader to pulse Aux2 when a valid access card is
presented. Set the reader using P318e, P328e or P338e.