telePHone nUmber 3 – test CAlls
Phone Number 3 is used to send Test Calls. If it is not programmed then Test Calls are
sent using Telephone No 1 & 2.
PROGRAMMING SeQUeNCe:
P80e
existing telephone number is displayed one digit at a time
[enTer neW TelePHone no] e
new telephone number is displayed one digit at a time
exAMPle: To program Telephone no.3 to be 03 2468 1234:
P80e0324681234e
P80e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
No telephone numbers.
relAteD oPtions
P89e 1e
enable test calls.
P83e
Test call interval.
P84e
Test call start delay.
telePHone nUmber 4 – CAllbACk
Phone Number 4 is used to prevent unauthorised up/download.
The panel will dial the callback telephone number to commence a NessComms™
up/download session.
NessComms™ up/download without callback is allowed by turning off option P90e 8e.
PROGRAMMING SeQUeNCe:
P81e
existing telephone number is displayed
[enTer neW TelePHone no] e
new Telephone No.4 is displayed one digit at a time
P81e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
No telephone numbers.
relAteD oPtions
P90e 8e enable Callback.
Dialler client codes can now be entered in Hexadecimal - as required by some
central stations. Use the following keys to enter the hex digits B, C, D, e or F.
HeX DIGIT
Key eNTRy
DISPlAyeD ON lCD DISPlAy
B
* Key
11
C
ARM Key
12
D
HOMe Key
13
e
eXClUDe Key
14
F
MeMORy key
15
HeX ACCOUNT NUMBeRS
notes
Note 1: If using the Ness leD keypad
for programming, the Hex digits will not
be displayed but are still programmed.
Note 2: Hex digit A is not allowed.
Note 3: entering Hex digits by
keypad applies to D8/D16 V4.6 and
later or previous versions by using
NessComms download software V4.62
or later.
ACCoUnt nUmber 1 & 2
Account numbers for identifying the panel to the Central Station. Area 1 Open/Close
reports will report on Account No.1 and Area 2 Open/Close reports will report on
Account No.2.
Zone Alarms can be assigned to report on either Account Number as set by Option
P79e.
All miscellaneous events (eg. Tampers, Mains Fail) will report on Account No. 1.
PROGRAMMING SeQUeNCe:
P72e
(or P73e)
existing account number is displayed one digit at a time
[enTer neW ACCoUnT no] e
new account number is displayed one digit at a time
exAMPle: To program Account no.1 to be 1239:
P72e1239e
P72e, P73e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
P72e Account No.1: 0000
P73e Account No.2: 0000
relAteD oPtions
P79e Account No.2 zones
39
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g