P120e 3e
note
This option enables Radio Key Home
Arming chirp s regardless of the state
of P64e 4e (Radio Key siren chirps).
relAteD oPtions
P69e 5e Radio key Home arm by ON/OFF
buttons.
P120e 4e
relAteD oPtions
P120e 1e latched Keyswitch.
P60e 2e, 3e Keyswitch options.
P120e 5e
relAteD oPtions
P120e 1e latched Keyswitch.
P60e 2e, 3e Keyswitch options.
P120e 6e
notes
• The zone causing the event is saved and
can be identified by viewing MeMORy. Only
one of the same consecutive zone warnings
is saved, although the MeMORy display will
flash each time (unless disabled by P94e
option).
• Smart Beeps work in addition to any other
outputs mapped to Home and Day alarms,
as programmed by options P63e 1e–8e.
• Smart Beeps work in conjunction with any
other Home and Day mode outputs, (as set
by options P63e 1e–8e).
P120e 7e
Available in D8x/D16x V5.6 and later.
relAteD oPtions
P26e entry Delay Time1.
P120e 8e
Available in D8x/D16x V5.6 and later.
relAteD oPtions
P60e 2e, 3e. P120e 1e, 4e, 5e.
rADio AUx bUtton Arms Home moDe
This option enables the AUX button on a Ness RK4 Radio Key to arm Home Mode.
When this option is enabled, options P122e 3e & 4e will be disabled, (AUX button to
Aux2 options. See page 60).
(This option is independent of P69e 5e, Home arming by radio key ON/OFF buttons).
oFF: no auX button Home arm. (Factory default). on: auX button Home arm enabled.
keysWitCH DisArm only
Converts the use of keyswitch operation using P60e 2e and 3e to only DISARM either
from Area or Home mode. Keyswitch operation must first be enabled using options
P60e 2e, 3e, page 24.
oFF: Keyswitch arms and disarms. (Factory default). on: Keyswitch disarms only.
keysWitCH Arm only
Converts the use of keyswitch operation using P60e 2e and 3e to only ARM either from
Area or Home mode.
Keyswitch operation must first be enabled using options P60e 2e, 3e, page 24 .
oFF: Keyswitch arms and disarms. (Factory default). on: Keyswitch arms only.
smArt beePs
Smart Beeps are available in Brief Home or Brief Day mode to identify zones by keypad
beeps.
When a Home zone or Day zone is triggered, the zone number is slowly beeped out,
followed by 2 seconds of silence. This is repeated 3 times and can be stopped by another
beep (such as keypress).
If the zone has entry delay you will hear the Smart Beeps sequence once when the zone is
triggered and again at the end of entry delay. If entry Beeps are disabled (P60e 1e), Smart
Beeps will only be heard at the end of entry delay.
Smart Beeps use the keypad/s onboard sonalert, so option P63e 3e and/or 7e must be on
to enable the sonalert output for Home alarms and Day alarms.
oFF: Smart Beeps disabled
. (Factory default). on: Smart Beeps enabled.
entry DelAy extenDer
Increases the entry Delay Time1 by a factor of 10. example, if P26e is programmed for
30 sec, it becomes 300 sec. (entry Delay Time2 is unaffected).
oFF: normal entry Delay time. (Factory default). on: entry Delay Multipled by 10.
AreA2 DisArm by keysWitCH AlloWeD
This option allows the keyswitch (if enabled) to disarm Area2. Note, the keyswitch
cannot arm Area2, only disarm. Though it can can both arm & disarm Area1.
oFF: option Disabled. (Factory default). on: option enabled.
57