Use reADer ADDresses
If ON then all readers connected to the D8x/D16x must have set addresses of 1, 2 or 3. The
data is then sent in an extended format that includes the reader address. (Use up to three
Ness prox readers). The reader's address is determined the connection of the violet wire.
See the wiring diagram on page 82).
If this option is off, one standard Weigand 26bit reader can be used. The reader's actions are
determined by the P318e, P319e Reader 1 options.
PROGRAMMING SeQUeNCe:
P301e 1e
toggles the option ON and OFF
off
: Do not use reader addresses
on
: use reader addresses
P301e 1e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF (Use one reader).
notes
When using multiple readers, this option
must be enabled before programming
any access cards, (to avoid losing card
programming when the option is enabled).
Arm WitH DoUble reAD
When this option is enabled the panel will arm if
the same
valid access card is
presented to a reader twice within 5 seconds.
PROGRAMMING SeQUeNCe:
P301e 2e
toggles the option ON and OFF
off
: Do not arm With Double read
on
: arm With Double read
P301e 2e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON.
Arm WitH single reAD AnD PUsHbUtton
When this option is enabled the panel will arm if a valid access card is presented to a
reader once and zone 8 is unsealed momentarily within 5 seconds.
This option can be used to prevent accidental arming or disarming by access card.
PROGRAMMING SeQUeNCe:
P301e 3e
toggles the option ON and OFF
off
: Do not arm With Single read and Pushbutton
on
: arm With Single read and Pushbutton
P301e 3e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF.
notes
• When this option is enabled, zone 8 is
automatically disabled as an alarm zone.
DisArm WitH ACCess CArD
When this option is enabled a valid access card will disarm the panel. (It will perform
the same function as a keypad code + e or a radio key off button).
PROGRAMMING SeQUeNCe:
P301e 4e
toggles the option ON and OFF
off
: Do not Disarm with access card
on
: Disarm with access card
P301e 4e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON.
reQUest to exit (rex) inPUts
These options convert zones 5, 6 and 7 into Request To exit (ReX) inputs for access
control, allowing for push button door exit. Connect a N/C or N/O pushbutton to either
open circuit or short circuit the zone resistor.
The ReX zones can also be programmed as long Response Zones (P37e, P38e) to
prevent accidental door opening, the ReX button must be pressed and held for 1sec or
3sec, as programmed.
P301e 5e enables Zone 5 to trigger the AUX outputs assigned to Reader1.
P301e 6e enables Zone 6 to trigger the AUX outputs assigned to Reader2.
P301e 7e enables Zone 7 to trigger the AUX outputs assigned to Reader3.
PROGRAMMING SeQUeNCe:
P301e 5e, 6e or 7e
toggles the option ON and OFF
oFF: the zone is a normal alarm zone
on: the zone is a reX input
P301e 5e–7e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF.
notes
• When one of these options is enabled,
that zone is automatically disabled as an
alarm zone.
• The zone must reseal before another
Request To exit can occur. i.e, If the zone
is left unsealed, the door will not be left
unlocked.
relAteD oPtions
P37e, P38e long Response Zones
P318e, P328e, P338e, P121e–P124e
Programming of Readers to Aux outputs.
Option No.
Description
Default
P301e
1e
Use reader addresses
OFF
2e
Arm with double read
ON
3e
Arm with single read and pushbutton
OFF
4e
Disarm with access card
ON
5e
ReX Input 1 (Zone 5 input)
OFF
6e
ReX Input 2 (Zone 6 input)
OFF
7e
ReX Input 3 (Zone 7 input)
OFF
8e
Strobe Flash on Arm/Disarm by Reader
ON
77
ACCess Control
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Содержание D16xD
Страница 94: ...NOTES ...
Страница 96: ......