AUto-time FeAtUres
D8x/D16x V6 onwards features sophisticated new automation features making full use of the onboard Real Time Clock
and a set of powerful yet simple to program options.
Autotimer 1
P350e
Minutes 0-59
30
P351e
Hours 0-23
18
P352e
Days (1=Sunday) 2, 3, 4, 5, 6
P353e
1e
AReA 1 ARM
ON
6e
KeyPAD Beeps
ON
8e
extend AutoTIMe
ON
P390e
AutoTime warning
10
exAmPle 1
AReA 1 to Auto Arm Monday to Friday at
6:30pm with warning beeps 10 minutes prior
to the event.
The keypad will start a slow continuous beep
at 6:20pm, then at 6:29pm the beeps change
to a faster rate for the final minute.
TO SIleNCe THe BeePS during the warning
period. Pressing any key on the keypad will
stop the beeps on the keypad (and the Reset
output) and then start again for the final
minute with a slightly faster beep.
TO DelAy ARMING enter a valid user code
on its own. (The user code must be assigned
to an Area to work). This will turn off the
warning beeps and the Auto Arm for 1 hour
- when the warning process will start again.
Autotimer 3
P360e
Minutes 0-59
00
P361e
Hours 0-23
07
P362e
Days (1=Sunday) 2, 3, 4, 5, 6
P363e
4e
Code enable
ON
exAmPle 3
User Code 56 is programmed to work only on
Monday-Friday between 7am to 5pm.
The user code will be disabled outside of
these times. (Applies only to keypad codes.
Radio keys and prox fobs will work anytime
regardless.)
In this example, if reporting to a central
station, the arming will be sent as User 91.
Autotimer 4
P365e
Minutes 0-59
00
P366e
Hours 0-23
07
P367e
Days (1=Sunday) 2, 3, 4, 5, 6
P368e
5e
Code Disable
ON
AutoTimer 3 Enables the user code.
AutoTimer 4 Disables the code.
e toggles extra Options
mode. See page 15.
9e
enable user Code
for AutoTime
P256e
User Code 56
ON
Enable Extra Option 9E for user code 56 to
enable the user code for use by AutoTime.
Programming steps
Programming steps
HOME
ARMED
ARMED
ARM or DISARM AUTOMATICAlly at pre-programmed times of day or day of the week.
This feature can save a site manager many headaches and hours of travel time. There is
no need to rely on staff remembering to arm or disarm the system.
TURN OUTPUTS ON or OFF at pre-programmed times - every day, once a week,
anytime. Automate doors, sprinkler systems, lights and more.
eNABle/DISABle USeR CODeS depending on the time of day or day of the week. Allows
managers to grant users access to the system at selected times and deny after hours entry.
This applies to keypad codes only, not radio keys or prox fobs.
The power and flexibility of AutoTime means it has numerous programmable options
which makes
nessComms software
the ideal programming tool.
The NessComms graphical user interface makes it easy to program complex options
on your PC or laptop. Then simply connect and download.
NessComms makes your life easier! See page 4 for further information.
1. For correct operation of Auto-Time features please ensure that the onboard clock is set to the current time and
date. See option P340-P345e, page 70.
2. D8/D16 version 8 and later has a real time clock onboard which does not rely on external timing signals.
Autotimer 2
P355e
Minutes 0-59
00
P356e
Hours 0-23
20
P357e
Days (1=Sunday) 7
P359e
6e
AUX1 PUlSe
ON
P145e
AUX1 Pulse Time
60
exAmPle 2
AUX1 turns on for one minute every
Saturday at 8pm.
This could be used to turn on sprinkers,
a pool or spa pump, lights or anything
that can be triggered by a relay output.
(Requires optional 106-013 Four Relay
Board).
Programming steps
TIp 1. The output can also be pulsed
on (or toggled on/off) anytime using
the 11* or 11# keypad commands.
See page 11.
TIp 2. For longer periods (up to a
week), a pair of AutoTimers can be
used - one to turn the AUX ON & the
other to turn it OFF.
69
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl