Page 178
11.18.5
Connection: Serial parameterization interface [X5]
Configuration on the device:
M8 flush-type socket, 3-pin type
Position:
front – right, see
Mating connector:
M8 mating connector for free configuration,
e.g. Phoenix SACC-M8MS-3CON-M-SH
Table 36: Pin assignment of connector [X5]
Pin no.
Name
Value
Specification
1
RxD
+/-10 V
Reception signal, RS232 specification
3
TxD
+/-10 V
Transmission signal, RS232 specification
4
GND
0 V
Reference potential for the serial interface, internally
connected with the common reference potential for the
intermediate circuit and the logic system
Table 37: Pin assignment to set up an RS232 adapter cable for connection to a PC/notebook
X5 pin assignment at
DUET_FL 48/10 FB
Dsub 9 connector (pin)
for connection to a PC
Specification
Pin no.
Name
Pin no.
Name
Specification
1
RxD
3
TxD_PC
Reception signal, RS232 specification
3
TxD
2
TxD_PC
Transmission signal, RS232 specification
4
GND
5
GND
Reference potential for the serial interface, internally
connected with the common reference potential for the
intermediate circuit and the logic system
-
Shield
-
Shield
Connect the cable shield on both sides of the
connector housing
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Содержание DUET_FL 48/10
Страница 3: ...ber dieses Handbuch Page 3...
Страница 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...