Page 47
Enter the maximum speeds and accelerations you are expecting for your application. The program
uses this information to limit the input fields.
The input limits can be changed later. They affect
only
the input fields of the
parametrization program!
Speeds and accelerations will
not
be limited physically in the drive! The quantities in the
drives can be limited in the
Safety parameters
menu described in
chapter 3.3 Selecting safety parameters
3.3 Selecting safety parameters
To protect the mechanical system from overload, the speed and acceleration values as well as the
movement range have to be limited to "safe" values for many applications. The setpoint values can be
limited in the menu
Parameters/Safety parameters
.
You can configure the following safety parameters in this window:
Decelerations:
Quick stop deceleration:
This deceleration will be used when the controller is no longer enabled or in the event of an
error (if possible).
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company