11.14. Mechanical installation
Important notes
The DUET_FL servo positioning controller was designed for direct installation on the motor.
Optionally it is also possible to use it separately from the motor. In this case, additional connecting
cables between the motor and the DUET_FL servo positioning controller are required. These
cables should be as short as possible. The maximum length is 1 m.
Optimum cooling can be ensured if the DUET_FL servo positioning controller is mounted in a
vertical position. This means that connector X1 is located on top or at the bottom.
The maximum permissible temperature of the housing is 70°C to guaranteed the specified service
life of the electronic system.
Connect the connecting cable for X1 as closely as possible to the DUET_FL servo positioning
controller to increase the reliability of the cabling.
Installation spaces:
Keep a minimum distance of 100 mm underneath and above the device to other components to
ensure sufficient ventilation.
Power
supply
Power
supply
U,V,W,
brake
Inputs/Outputs
Communication
DIS-2
DIS-2
Motor
Motor
feedback
a)
b)
Inputs/Outputs
DUET_FL mounting options:
a) Mounted directly on the motor - standard
b) Separated from the motor - Please contact your local distributor to check whether this
option is available.
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Содержание DUET_FL 48/10
Страница 3: ...ber dieses Handbuch Page 3...
Страница 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...