Page 20
Full integration of all components for the controller and power section, including an RS232
interface for PC communication and a CANopen interface for integration in automation
systems.
Integrated universal rotary encoder evaluation for the following encoder types:
Resolvers
Analog Hall sensors with SIN/COS signals (upon request)
High-resolution Stegmann incremental encoders, absolute encoders with HIPERFACE
Six-step Hall encoders
Incremental encoders with commutation signals
Integrated driver stage for 24 V holding brakes
Compliance with current CE and EN standards without any additional external filter measures
EMC-optimized metal housing for direct mounting on the motor. The device has an IP54
degree of protection. Depending on the mounting methods and the seals used, a degree of
protection up to IP67 can be reached.
Integration of all filters in the unit required for compliance with the EMC regulations (industrial
environment), e.g. filters for the 24 V supply and the inputs and outputs.
Can be used as a torque controller, speed controller or position controller.
Integrated positioning control with extensive functionality in accordance with "CAN in
Automation (CiA) DSP402" and numerous additional application-specific functions.
Jerk-free or time-optimal positioning, relative or absolute with regard to a reference point.
Point-to-point positioning with and without spot tracing.
Speed- and angle-synchronous operation with an electronic gearbox via field bus.
Numerous homing methods.
Changeable clock frequency for the output stage.
Integrated course program to create simple positioning sequences with or without dependence
on digital inputs.
Programmable digital outputs.
High-resolution 12-bit analog input.
User-friendly parametrization using the DUET_FL ServoCommander
TM
PC program.
Automatic motor identification.
Easy connection to a superordinated control system, e.g. to a PLC on the I/O level or via a field
bus.
Technology slot for extensions, e.g. field bus connections (only DUET_FL 48/10)
I²t monitoring system to limit the average power loss in the power stage and in the motor.
Integrated brake chopper (only DUET_FL 48/10)
Separate RS232 and field bus connection (only DUET_FL 48/10)
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Содержание DUET_FL 48/10
Страница 3: ...ber dieses Handbuch Page 3...
Страница 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...