Page 111
Error
no.
CAN
error
code
Meaning
Possible causes / measures
Release
time
Reaction
C E
W
error
Check the baud rate setting
Check the node number setting - node
used more than once in the network?
56
7510
RS232
communication
error
Communication disturbed: Check the
installation under EMC aspects.
< 5ms
X X X
57
6191
Error position
data set
Conflict between acceleration and running
speed.
Please contact the technical support team.
< 5ms
X
58
6380
Error: Operating
mode
Change of operating mode while the power
stage is switched on.
< 5ms
X X X
60
6190
Error: Pos.
precomputation
Internal error.
Please contact the technical support team.
< 5ms
X
62
6180
Stack overflow
Internal error.
Please contact the technical support team.
< 5ms
X
63
5581
Check sum error
Internal error.
Please contact the technical support team.
< 5ms
X
64
6187
Initialization error
Internal error.
Please contact the technical support team.
< 5ms
X
The servo positioning controller internally manages the error no. 1 to no. 64.
If your device displays an error number which is not described in the error table and
marked as an "unknown error" in
chapter 6.2 Error management
, please contact your
local distributor.
It is possible to assign these error numbers for firmware extensions or customized
firmware versions with additional monitoring functions.
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Содержание DUET_FL 48/10
Страница 3: ...ber dieses Handbuch Page 3...
Страница 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...