Page 112
Error display in DUET_FL ServoCommander
TM
The
error window
is a permanent window in the parameterization program. If there is no error, the
window is minimized.
In the event of a controller error, the user interface changes in two ways:
1. The error window will be maximized and put to the surface.
2. The error will be stated in red writing on the lower bar of the main window.
Errors are handled in three steps:
1.
Error analysis:
In the example given here, the error is caused by a broken/unconnected
connection to the angle encoder.
2.
Error elimination:
Eliminate the cause of the error. (In this example, the correct connection
to the angle encoder has to be provided.)
3.
Error acknowledgement:
Click on the
Clear
button in the error window. If the error was
successfully eliminated, the window will be minimized. If the error still exists, it will be
maximized again.
You can minimize the window by clicking the
Cancel
button. Any existing error message will remain in
the error window on the status bar.
The
Cancel
button does not eliminate any error!
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Содержание DUET_FL 48/10
Страница 3: ...ber dieses Handbuch Page 3...
Страница 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...