Page 141
Error word (low) (errh_err_field_0)
Bit
Meaning
31
30
Error limit switch
29
28
Following error monitoring
27
Output stage temperature 5°C below maximum
26
Motor temperature 5°C below maximum
25
I²T at 80%
24
23
22
21
20
19
Controller I
2
T error (I
2
T at 100%)
18
Motor I
2
T error (I
2
T at 100%)
17
16
SINCOS track signal error
15
Intermediate circuit overvoltage
14
Intermediate circuit undervoltage
13
Overcurrent intermediate circuit / output stage
12
Current measurement offset error
11
10
24V supply error (out of range)
9
12V electronic system supply error
8
5V electronic system supply error
7
Resolver track signal error / carrier failure
6
SINCOS track signal error
5
SINCOS RS485 communication error
4
SINCOS supply error
3
Electronic power system under-/overtemperature
2
Motor overtemperature
1
0