Page 120
Clicking the radio button
Exit program
immediately terminates the parameterization program.
The following table describes possible error causes the error elimination strategies:
Table 19: Recovering problems with serial communication
Cause
Measure
Communication error
Click on
Retry with old parameters
.
Wrong COM-port selected
Click on
Change COM-port
and follow the instructions.
The baud rate of the parameterization program
does not match the baud rate of the servo
positioning controller.
Click on
Search baud rates
.
The communication of the servo positioning
controller is disturbed.
RESET
the servo positioning controller, i.e. switch it off and on
again. Then click on
Retry with old parameters
.
Hardware error:
Servo positioning controller not switched
on
Eliminate the error and then click on
Retry with old parameters
.
Connecting cable disconnected
Connecting cable broken
Incorrect pin assignment for the serial
connection
Connecting cable too long
Reduce the baud rate or use a shorter cable.
User Manual DUET_FL „DUET_FL 48/10“
Version 1.1 Motor Power Company
Содержание DUET_FL 48/10
Страница 3: ...ber dieses Handbuch Page 3...
Страница 4: ...Page 4 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 12: ...Page 12 List of Figures User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 15: ...Page 15 List of Tables User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 76: ...Page 76 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...
Страница 196: ...Page 196 User Manual DUET_FL DUET_FL 48 10 Version 1 1 Motor Power Company...