10.3 Alarm Message List
10-38
4308
VOLTAGE DROP
(CONVERTER)
[Bit Pattern]
• Direct current power supply voltage sup-
plied to amplifier for servopack has
become less than143V.
Reason is follows:
• Primary power supply voltage was too low.
• There was open phase.
• Defective converte
• Defective WRCA01circuit boar
• Check the connection for primary side
wiring R,S,T, wire.
• Check that power supply voltage is more
than 170V.
• If the error occurs again, replace the
WRCA01, WRCF01 circuit board, the
converter.
4309
DEFECTIVE
ENCODER INTER-
NAL DATA
Robot/Station
[Axis Data]
The internal parameter error for serial
encoder. It is thought the encoder was
abnormal.
• Turn the power off then back on. If a
phenomenon occurs again after repeat-
ing this operation several times, replace
the motor (encoder) for axis occurred the
error.
• If the error occurs again, consult with a
YASKAWA representative.
4310
ENCODER OVER-
HEAT
Robot/Station
[Axis Data]
The encoder has overheated to 100
degrees.
• Check that the ambient temperature is
not too high.
• Check the load again.
• Check the primary power supply voltage
(220V+10%).
• If the error occurs again, replace the
WRCA01 circuit board, the encoder.
4311
ENCODER BACK-UP
ERROR
Robot/Station
[Axis Data]
• Because backup power supply voltage for
encoder decreased (less than 2.6V), posi-
tion data of the encoder disappeared.
• Whenever a new motor was used, this
error occurred.
• Reset the alarm. Adjust the home posi-
tion again.
• Check the battery voltage for encoder.
(more than 2.8V)
• Replace the battery.
• If the error occurs again, replace the
encoder.
• Because it is charged the backup con-
denser, don't turn off power supply for a
few minutes.
4312
ENCODER BAT-
TERY ERROR
Robot/Station
[Axis Data]
Voltage of backup battery for encoder has
decreased.(less than 2.8V)
(In case leaving this voltage as it is, the
backup error occurs and position data dis
appears.)
• Check the battery voltage for encoder.
(more than 2.8V)
• Replace the battery.
4313
SERIAL ENCODER
OVER HEAT
Robot/Station
[Axis Data]
The encoder has overheated to 100
degrees.
• Check that the ambient temperature is
not too high.
• Check the load again.
• Check the primary power supply voltage
(220V+10%).
• If the error occurs again, replace the
WRCA01 circuit board, the encoder.
4314
SERIAL ENCODER
BATTERY ERROR
Robot/Station
[Axis Data]
Voltage of backup battery for encoder has
decreased.(less than 2.8V)(In case leaving
this voltage as it is, the backup error occurs
and position data disappears.
• Check the battery voltage for encoder.
(more than 2.8V)
• Replace the battery.
Alarm Message List
Alarm
Number
Message
Cause
Remedy
Содержание PX2750
Страница 2: ......
Страница 4: ...PX2850 PX2750 Manipulator Manual ii MOTOMAN NOTES...
Страница 20: ...viii...
Страница 24: ...xii...
Страница 40: ...1 7 Notes on MOTOMAN Disposal 1 16...
Страница 58: ...4 3 Connection Methods 4 12...
Страница 66: ...6 1 Movement of the Axes 6 4...
Страница 72: ...8 2...
Страница 73: ......
Страница 99: ......
Страница 100: ......
Страница 282: ...2 8 General I O Signal Assignment 2 72...
Страница 318: ...4 4 Recommended Spare Parts 4 30...
Страница 333: ...xiv...
Страница 334: ...Setup Diagnosis...
Страница 335: ......
Страница 337: ...1 2...
Страница 345: ...2 1 Protection Through Security Mode Settings 2 8...
Страница 443: ...3 17 File Initialize 3 98...
Страница 465: ...4 2 Addition of Base and Station Axis 4 22...
Страница 483: ...5 6 Position Data When Power is Turned ON OFF 5 18...
Страница 484: ...Hardware...
Страница 485: ......
Страница 495: ...6 4 Equipment Configuration 6 10...
Страница 497: ...7 2...
Страница 505: ...8 8 Open Phase Check 8 8...
Страница 525: ...9 4 Recommended Spare Parts 9 20...
Страница 526: ...Alarm Error...
Страница 527: ......
Страница 573: ......
Страница 574: ......
Страница 575: ......
Страница 576: ......
Страница 577: ......
Страница 578: ......
Страница 579: ......
Страница 580: ......
Страница 581: ......
Страница 582: ......
Страница 583: ......
Страница 584: ......
Страница 585: ......
Страница 586: ......
Страница 587: ......
Страница 588: ......
Страница 589: ......
Страница 590: ......
Страница 591: ......
Страница 592: ......
Страница 593: ......
Страница 594: ......
Страница 595: ......
Страница 596: ......
Страница 597: ......
Страница 598: ......
Страница 599: ......
Страница 600: ......
Страница 601: ......
Страница 602: ......
Страница 603: ......
Страница 604: ......
Страница 605: ......
Страница 606: ......
Страница 607: ......
Страница 608: ......
Страница 609: ......
Страница 610: ......
Страница 611: ......