1. PREPARATORY PROCEDURES FOR MONITORING
1.6 Checking for Normal Monitoring
1 - 49
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
D
E
VICE RA
NGE
T
H
A
T
CAN
B
E
SET
3
ACCESS
RA
N
G
E
F
O
R MONIT
O
R
ING
4
HOW T
O
MONIT
O
R
REDUNT
ANT
SYS
TEM
5
BUS CONNECTION
6
DIR
E
CT
CONNECTION T
O
CPU
7
COMP
UT
E
R
L
INK
CONNE
C
T
ION
8
E
T
HE
RN
E
T
CONN
E
C
T
ION
(2) Faulty station information (GS231 to GS238)
The bit corresponding to the faulty station is set.(0: Normal, 1: Abnormal)
The bit is reset after the fault is recovered.
(a) Ethernet connection (Except for Ethernet multiple connection)
(b) Ethernet multiple connection, servo amplifier connection, inverter connection
The station number to which each device corresponds changes according to the connection/non
connection with Ethernet.
With Ethernet connection: 1 to 128
With other than Ethernet connection: 0 to 127
Example) With Ethernet connection, when PC No. 100 CPU connecting to Ch3 is faulty, GS327.b3 is set.
The following table shows the case with Ethernet connection.
For details on the GS Device, refer to the following manual.
GT Designer3 Screen Design Manual (Fundamentals) Appendix.2.3 GOT special register (GS)
GS231 bit 0
GS231 bit 1
GS231 bit 2
GS231 bit 3
Device
PLC No.
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
GS231
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
GS232
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
GS233
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
GS234
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
GS235
80
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
GS236
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
GS237
112
111
110
109
108
107
106
105
104
103
102
101
100
99
98
97
GS238
128
127
126
125
124
123
122
121
120
119
118
117
116
115
114
113
Device
PLC No./Station No.
Ch1
Ch2
Ch3
Ch4
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
GS281
GS301
GS321
GS341
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
GS282
GS302
GS322
GS342
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
GS283
GS303
GS323
GS343
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
GS284
GS304
GS324
GS344
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
GS285
GS305
GS325
GS345
80
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
GS286
GS306
GS326
GS346
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
GS287
GS307
GS327
GS347
112
111
110
109
108
107
106
105
104
103
102
101
100
99
98
97
GS288
GS308
GS328
GS348
128
127
126
125
124
123
122
121
120
119
118
117
116
115
114
113
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......