23 - 18
23. FA TRANSPARENT FUNCTION
23.3 List of Models that Can Be Monitored
(Continued to next page)
*1
Use the serial port of QCPU in the multiple CPU system since only the USB port is available as the direct coupled I/F for Q172H/
Q173HCPU.
*2
Use the serial port of QCPU in the multiple CPU system since Q172H/Q173HCPU has no direct coupled I/F.
*3
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
*4
Do not execute the write during RUN in the bus connection.
*5
MT Works2 or GX Developer does not support the FA transparent function through CC-Link IE Controller Network.
Series
Model name
Target software
Connection type
Bus
connection
Direct CPU connection
Computer link connection
Ethernet
connection
CC-Link IE
Controller
Network
connection
*3
MELSEC-A
(AnSCPU)
A2USCPU
GX Developer
MX Component
MX Sheet
A2USCPU-S1
A2USHCPU-S1
A1SCPU
A1SCPUC24-R2
A1SHCPU
A2SCPU
*1
A2SCPU-S1
A2SHCPU
A2SHCPU-S1
A1SJCPU
A1SJCPU-S3
A1SJHCPU
MELSEC-A
A0J2HCPU
GX Developer
MX Component
MX Sheet
*4
A0J2HCPUP21
A0J2HCPUR21
A0J2HCPU-DC24
A2CCPU
GX Developer
MX Component
MX Sheet
A2CCPUP21
A2CCPUR21
A2CCPUC24
A2CCPUC24-PRF
A2CJCPU-S3
A1FXCPU
Motion
controller CPU
(Q Series)
Q172CPU
MT Developer
Q173CPU
Q172CPUN
Q173CPUN
Q172HCPU
MT Developer
MR Configurator
*1
*1
*1
Q173HCPU
Q172DCPU
MT Works2
*2
*2
*2
Q173DCPU
Q172DCPU-S1
Q173DCPU-S1
Q172DSCPU
Q173DSCPU
Q170MCPU
MT Works2
*5
GX Developer
*5
GX Works2
Q170MSCPU
Q170MSCPU-S1
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......