16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
16 - 55
9
ME
LSE
C
NE
T
/H
CONN
E
C
TION
(P
LC
T
O
P
L
C NE
T
W
ORK)
10
MELSE
C
N
E
T/10
C
O
NNECTION (P
LC
TO
PL
C
N
E
T
W
O
R
K
)
11
C
C
-L
ink
IE
CO
NT
RO
LLER
NE
TW
ORK
CON
N
E
CTI
O
N
12
CC-Link
IE FIELD
NETWO
RK
CONNE
CTION
13
CC-
Li
nk
CONNECTI
O
N
(IN
TEL
LI
G
E
NT
DEVI
C
E
ST
AT
IO
N)
14
CC-Lin
k
CONNECTION (V
ia G4)
15
IN
VER
TER
CONNE
C
T
ION
16
SE
R
V
O AM
P
L
IFI
E
R
CONN
E
C
T
ION
ALM18
Servo status when alarm occurs regenerative
load ratio
―
ALM19
Servo status when alarm occurs effective load
ratio
―
ALM20
Servo status when alarm occurs peak load ratio
―
ALM21
Servo status when alarm occurs instantaneous
torque
―
ALM22
Servo status (alarm) Within one-revolution
position (1 pulse unit)
―
ALM23
Servo status when alarm occurs ABS counter
―
ALM24
Servo status (alarm) load inertia moment ratio
―
ALM25
Servo status when alarm occurs bus voltage
―
ALM26
Servo status (alarm) Load-side cumulative
feedback pulses
―
ALM27
Servo status (alarm) Load-side droop pulses
―
ALM28
Servo status (alarm) Load-side encoder
information 1
―
ALM29
Servo status (alarm) Load-side encoder
information 2
―
ALM30 to
ALM32
For manufacturer setting
―
ALM33
Servo status (alarm) Temperature of servo
motor thermistor
―
ALM34
Servo status (alarm) Servo motor-side
cumulative feedback pulses (before gear)
―
ALM35
Servo status (alarm) Electrical angle
―
ALM36 to
ALM40
For manufacturer setting
―
ALM41
Servo status (alarm) Servo motor-side/load-side
position deviation
―
ALM42
Servo status (alarm) Servo motor-side/load-side
speed deviation
―
ALM43
Servo status (alarm) Internal temperature of
encoder
―
ALM44
Servo status (alarm) Setting time
―
ALM45
Servo status (alarm) Oscillation detection
frequency
―
ALM46
Servo status (alarm) Number of tough drives
―
ALM47 to
ALM50
For manufacturer setting
―
ALM51
Servo status (alarm) Unit power consumption
―
ALM52
Servo status (alarm) Unit total power
consumption
―
ALM53
Servo status when alarm occurs current position
―
ALM54
Servo status when alarm occurs command
position
―
ALM55
Servo status when alarm occurs command
remaining distance
―
ALM56
Servo status (alarm) Point table No./Program
No./Station position No.
―
ALM57
Servo status (alarm) Step No.
―
ALM58
Servo status (alarm) Analog override voltage
―
ALM59
Servo status (alarm) Override level
―
ALM200
Alarm number from Alarm History most recent
alarm
―
ALM201
Alarm number from Alarm History 1st alarm in
past
―
ALM202
Alarm number from Alarm History 2nd alarm in
past
―
ALM203
Alarm number from Alarm History 3rd alarm in
past
―
Device
name
Item
Symbol
ALM204
Alarm number from Alarm History 4th alarm in
past
―
ALM205
Alarm number from Alarm History 5th alarm in
past
―
ALM206
Alarm number from Alarm History 6th alarm in
past
―
ALM207
Alarm number from Alarm History 7th alarm in
past
―
ALM208
Alarm number from Alarm History 8th alarm in
past
―
ALM209
Alarm number from Alarm History 9th alarm in
past
―
ALM210
Alarm number from Alarm History 10th alarm in
past
―
ALM211
Alarm number from Alarm History 11th alarm in
past
―
ALM212
Alarm number from Alarm History 12th alarm in
past
―
ALM213
Alarm number from Alarm History 13th alarm in
past
―
ALM214
Alarm number from Alarm History 14th alarm in
past
―
ALM215
Alarm number from Alarm History 15th alarm in
past
―
ALM220
Alarm occurrence time in alarm history most
recent alarm
―
ALM221
Alarm occurrence time in alarm history 1st
alarm in past
―
ALM222
Alarm occurrence time in alarm history 2nd
alarm in past
―
ALM223
Alarm occurrence time in alarm history 3rd
alarm in past
―
ALM224
Alarm occurrence time in alarm history 4th
alarm in past
―
ALM225
Alarm occurrence time in alarm history 5th
alarm in past
―
ALM226
Alarm occurrence time in alarm history 6th
alarm in past
―
ALM227
Alarm occurrence time in alarm history 7th
alarm in past
―
ALM228
Alarm occurrence time in alarm history 8th
alarm in past
―
ALM229
Alarm occurrence time in alarm history 9th
alarm in past
―
ALM230
Alarm occurrence time in alarm history 10th
alarm in past
―
ALM231
Alarm occurrence time in alarm history 11th
alarm in past
―
ALM232
Alarm occurrence time in alarm history 12th
alarm in past
―
ALM233
Alarm occurrence time in alarm history 13th
alarm in past
―
ALM234
Alarm occurrence time in alarm history 14th
alarm in past
―
ALM235
Alarm occurrence time in alarm history 15th
alarm in past
―
ALM240
Detailed alarm from Alarm History most recent
alarm
―
ALM241
Detailed alarm from Alarm History 1st alarm in
past
―
ALM242
Detailed alarm from Alarm History 2nd alarm in
past
―
Device
name
Item
Symbol
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......