16.6 Device Range that Can Be Set
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(e) Status display
(f) Alarm
Device name
Item
Symbol
*1
PRM24, PRM1024
Zero speed
ZSP
PRM25 to PRM26,
PRM1025 to PRM1026
For manufacturer setting
―
PRM27, PRM1027
Encoder output pulses
*ENR
PRM28, PRM1028
Internal torque limit 1
TL1
PRM29 to PRM32,
PRM1029 to PRM1032
For manufacturer setting
―
PRM33, PRM1033
Electromagnetic brake
sequence output
MBR
PRM34, PRM1034
Ratio of load inertia moment
to servo motor inertia
moment
GD2
PRM35, PRM1035
Position loop gain 2
PG2
PRM36, PRM1036
Speed loop gain 1
VG1
PRM37, PRM1037
Speed loop gain 2
VG2
PRM38, PRM1038
Speed integral
compensation
VIC
PRM39, PRM1039
Speed differential
compensation
VDC
PRM40 to PRM41,
PRM1040 to PRM1041
For manufacturer setting
―
PRM42, PRM1042
Input signal selection 1
*DI1
PRM43 to PRM50,
PRM1043 to PRM1050
For manufacturer setting
―
PRM51, PRM1051
Function selection 6
*OP6
PRM52 to PRM53,
PRM1052 to PRM1053
For manufacturer setting
―
PRM54, PRM1054
Function selection 9
*OP9
PRM55, PRM1055
Function selection A
*OPA
PRM56 to PRM57,
PRM1056 to PRM1057
For manufacturer setting
―
PRM58, PRM1058
Machine resonance
suppression filter 1
NH1
PRM59, PRM1059
Machine resonance
suppression filter 2
NH2
PRM60, PRM1060
Low-pass filter,
adaptive vibration
suppression control
LPF
PRM61, PRM1061
Ratio of load inertia moment
to servo motor inertia
moment 2
GD2B
PRM62, PRM1062
Position control gain 2
changing ratio
PG2B
PRM63, PRM1063
Speed control gain 2
changing ratio
VG2B
PRM64, PRM1064
Speed integral compensation
changing ratio
VICB
PRM65, PRM1065
Gain changing selection
*CDP
PRM66, PRM1066
Gain changing condition
CDS
PRM67, PRM1067
Gain changing time constant
CDT
PRM68, PRM1068
For manufacturer setting
―
PRM69, PRM1069
Command pulse multiplying
factor numerator 2
CMX2
PRM70, PRM1070
Command pulse multiplying
factor numerator 3
CMX3
PRM71, PRM1071
Command pulse multiplying
factor numerator 4
CMX4
PRM72 to PRM75,
PRM1072 to PRM1075
For manufacturer setting
―
PRM76, PRM1076
Internal torque limit 2
TL2
PRM77 to PRM84,
PRM1077 to PRM1084
For manufacturer setting
―
Device name
Item
Symbol
ST0
Cumulative feedback pulses
―
ST1
Servo motor speed
―
ST2
Droop pulses
―
ST3
Cumulative command pulses
―
ST4
Command pulse frequency
―
ST5
Effective load ratio
―
ST6
Peak load ratio
―
ST7
Instantaneous torque
―
ST8
Within one-revolution position
―
ST9
ABS counter
―
ST10
Load inertia moment ratio
―
Device
name
Item
Symbol
AL0
Current alarm number
―
AL11
Servo status when alarm occurs cumulative
feedback pulses
―
AL12
Servo status when alarm occurs
servo motor speed
―
AL13
Servo status when alarm occurs droop
pulses
―
AL14
Servo status when alarm occurs cumulative
command pulses
―
AL15
Servo status when alarm occurs command
pulse frequency
―
AL16
Servo status when alarm occurs effective
load ratio
―
AL17
Servo status when alarm occurs peak load
ratio
―
AL18
Servo status when alarm occurs
instantaneous torque
―
AL19
Servo status when alarm occurs within one-
revolution position
―
AL20
Servo status when alarm occurs ABS
counter
―
AL21
Servo status when alarm occurs
load inertia moment ratio
―
AL200
Alarm number from alarm history
most recent alarm
―
AL201
Alarm number from alarm history
first alarm in past
―
AL202
Alarm number from alarm history
second alarm in past
―
AL203
Alarm number from alarm history
third alarm in past
―
AL204
Alarm number from alarm history
fourth alarm in past
―
AL205
Alarm number from alarm history
fifth alarm in past
―
AL210
Alarm occurrence time in alarm history
most recent alarm
―
AL211
Alarm occurrence time in alarm history
first alarm in past
―
AL212
Alarm occurrence time in alarm history
second alarm in past
―
AL213
Alarm occurrence time in alarm history
third alarm in past
―
AL214
Alarm occurrence time in alarm history
fourth alarm in past
―
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......