1 - 20
1. PREPARATORY PROCEDURES FOR MONITORING
1.3 Option Devices for the Respective Connection
1.3.7
Installing a unit on another unit (Checking the unit installation position)
This section describes the precautions for installing units on another unit.
For the installation method of each unit, refer to the User's Manual for the communication unit and option unit you are
using.
For the method for installing a unit on another unit, refer to the following.
User's Manual of GOT used.
Calculating consumed current
For using multiple extension units, a bar code reader, or a RFID controller, the total current for the extension units,
bar code reader, or RFID controller must be within the current that the GOT can supply.
For the current that the GOT can supply and the current for the extension units, bar code reader, or RFID controller,
refer to the following tables. Make sure that the total of consumed current is within the capacity of the GOT.
(1) Current supply capacity of the GOT
(2) Current consumed by an extension unit/barcode reader/RFID controller
*1
Value used for calculating the current consumption of the multi-channel function.
For the specifications of the unit, refer to the manual included with the unit.
*2
When the GOT supplies power to a barcode reader or a RFID controller from the standard interface, add their consumed current.
(Maximum value is less than 0.3 A)
GOT type
Current supply
capacity
(A)
GOT type
Current supply
capacity
(A)
GT1695M-X
2.4
GT1595-X
2.13
GT1685M-S
2.4
GT1585V-S
1.74
GT1675M-S
2.4
GT1585-S
1.74
GT1675M-V
2.4
GT1575V-S
2.2
GT1675-VN,
GT1672-VN
2.4
GT1575-S
2.2
GT1665M-S
2.4
GT1575-V,
GT1572-VN
2.2
GT1665M-V
2.4
GT1565-V,
GT1562-VN
2.2
GT1662-VN
2.4
GT1555-V
1.3
GT1655-V
1.3
GT1555-Q,
GT1550-Q
1.3
Module type
Consumed
current
(A)
Module type
Consumed
current
(A)
GT15-QBUS,
GT15-QBUS,
GT15-75QBUSL,
GT15-75QBUS2L
0.275
*1
GT16M-R2
0
*1
GT15-ABUS,
GT15-ABUS2,
GT15-75ABUSL,
GT15-75ABUS2L
0.12
GT15V-75R1
0.2
*1
GT15-RS2-9P
0.29
GT16M-V4R1
0.12
*1
GT15-RS4-9S
0.33
GT15V-75V4R1
0.2
*1
GT15-RS4-TE
0.3
GT16M-ROUT
0.11
*1
GT15-RS2T4-9P
0.098
GT15V-75ROUT
0.11
GT15-J71E71-100
0.224
GT16M-MMR
0.27
*1
GT15-J71GP23-SX
1.07
GT15-CFCD
0.07
GT15-J71LP23-25
0.56
GT15-CFEX-C08SET
0.15
GT15-J71BR13
0.77
GT15-SOUT
0.08
GT15-J61BT13
0.56
GT15-DIO
0.1
Bar code reader
*2
GT15-DIOR
0.1
GT15-PRN
0.09
RFID controller
*2
GT16M-V4
0.12
*1
GT15-80FPA
0.22
GT15V-75V4
0.2
*1
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......