7 - 4
7. COMPUTER LINK CONNECTION
7.1 Connectable Model List
(Continued to next page)
*1
Use only modules with the upper five digits of the serial No. later than 12042.
*2
Use the serial port of a serial communication module controlled by another CPU on the multiple CPU.
*3
If the A series computer link module is applied to the QnACPU, the GOT can monitor the devices in the same range on AnACPU.
However, the following devices cannot be monitored.
• Devices added to QnACPU
• Latch relays (L) and step relays (S)
(In case of QnACPU, the latch relay (L) and step relay (S) are different from the internal relay. However, whichever is specified,
an access is made to the internal relay.)
• File register (R)
Series
Model name
Clock
Communication
Refer to
C Controller
module
(Q Series)
Q12DCCPU-V
*1*2
Q24DHCCPU-V
*2
/VG
*2
Q24DHCCPU-LS
RS-232
RS-422
Q26DHCCPU-LS
MELSEC-QS
QS001CPU
-
-
MELSEC-L
L02CPU
L06CPU
L26CPU
L26CPU-BT
L02CPU-P
L06CPU-P
L26CPU-P
L26CPU-PBT
L02SCPU
L02SCPU-P
RS-232
RS-422
MELSEC-Q
(A mode)
Q02CPU-A
Q02HCPU-A
Q06HCPU-A
RS-232
RS-422
MELSEC-QnA
(QnACPU)
*3
Q2ACPU
Q2ACPU-S1
Q3ACPU
Q4ACPU
RS-232
RS-422
Q4ARCPU
RS-232
RS-422
MELSEC-QnA
(QnASCPU)
*3
Q2ASCPU
Q2ASCPU-S1
Q2ASHCPU
Q2ASHCPU-S1
RS-232
RS-422
MELSEC-A
(AnCPU)
A2UCPU
A2UCPU-S1
A3UCPU
A4UCPU
A2ACPU
A2ACPUP21
A2ACPUR21
A2ACPU-S1
A2ACPUP21-S1
A2ACPUR21-S1
A3ACPU
A3ACPUP21
A3ACPUR21
A1NCPU
A1NCPUP21
A1NCPUR21
A2NCPU
A2NCPUP21
A2NCPUR21
A2NCPU-S1
A2NCPUP21-S1
A2NCPUR21-S1
A3NCPU
A3NCPUP21
A3NCPUR21
RS-232
RS-422
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......