Table 10:
IEEE 95 for HiPot test.
V Line
Per Unit
Min Test,
V Line x 1.25 x 1.7
Max Test,
VLine x 1.5 x 1.7
480
392
1,020
1,224
575
469
1,222
1,466
600
490
1,275
1,530
2,300
1,878
4,888
5,865
4,160
3,397
8,840
10,608
6,900
5,634
14,663
17,595
13,800
11,268
29,325
35,190
Table 11:
NEMA MG-1/EASA AR100 DC-HiPot.
V Line
Per Unit
New, 3.4 × V Line + 1,700
In Service, 65% of New
480
392
3,332
2,165.8
575
469
3,655
2,375.75
600
490
3,740
2,431
2,300
1,878
9,520
6,188
4,160
3,397
15,844
10,298.6
6,900
5,634
25,160
16,354
13,800
11,268
48,620
31,603
Table 12:
IEEE 522 Surge testing.
V Line
Per Unit
New, 3.5 × Per Unit
In Service, 75% of New
480
392
1,372
1,029
575
469
1,642
1,232
600
490
1,715
1,286
2,300
1,878
6,573
4,930
4,160
3,397
11,890
8,917
6,900
5,634
19,719
14,789
13,800
11,268
39,438
29,578
Table 13:
IEC 34-15.
V Line
Per Unit
V Line × 4E + 5,000
0.2 us, 65%
480
392
6,920
4,498
575
469
7,300
4,745
600
490
7,400
4,810
2,300
1,878
14,200
9,230
4,160
3,397
21,640
14,066
6,900
5,634
32,600
21,190
13,800
11,268
60,200
39,130
www.megger.com
Megger Baker ADX User Guide
164
Recommended DC HiPot and Surge Test Voltages
Содержание ADX15
Страница 1: ...Megger Baker ADX Automated Diagnostic Test Equipment User Guide...
Страница 2: ...www megger com Megger Baker ADX User Guide...
Страница 10: ...www megger com Megger Baker ADX User Guide viii Table of Contents...
Страница 44: ...www megger com Megger Baker ADX User Guide 34...
Страница 84: ...www megger com Megger Baker ADX User Guide 74 Routes...
Страница 148: ...www megger com Megger Baker ADX User Guide 138...
Страница 172: ...www megger com Megger Baker ADX User Guide 162...