Message
Description
Appears in
Asset exists in Installation _________
User tried to delete an asset that
has been assigned to one or more
installations.
Asset editor.
Results exist for asset _________
User tried to delete an asset that has
test results saved in the database.
Asset editor.
Assets are using this test config.
Delete?
User tried to delete a Test
Configuration that has been assigned
to one or more assets.
Test Configuration editor.
Download Failed
Failure to download a software
update.
Login screen.
Unable To contact software server,
please check internet connection and
retry.
User tried to check for software
updates, but internet connection was
too weak or out of range for Wi-Fi,
and not connected via Ethernet.
Login screen.
Internal Thermal Temp. too high, must
cool down
Software detects that the ADX is
overheating.
All modes.
Power supply open ground detected
Open ground override not turned on.
HiPot, Surge, and Coil (high-voltage
testing.
Faulty test initiation control
PTT button not working. Holding PTT
button before going into test.
HiPot, Surge, and Coil (high-voltage
testing.
This load does not appear to be
capacitive
User tried to run a capacitance test on
an asset that is not capacitive. Also,
appears if leads are not switched
during RLC test as instructed.
All RLC tests.
This load does not appear to be
inductive
User tried to run an inductance test on
an asset that is not inductive.
All RLC tests.
To use PD while manually testing, have
an Asset selected
User tried to execute a Surge test with
PD while in Manual mode.
Manual Surge mode.
Test limit exceeded
General message for all RLC tests (and
others with limits).
All tests using limits.
Cannot delete active connection
User tried to use The Delete button to
remove the active connection.
Realm Cloud Connection screen.
PD testing can only be used with Host
selected as output device
User tried to execute a Surge test with
PD while output device is not set to
Host.
All Surge modes.
The entered reference waveform name
is not unique.
User tried to save a new Surge test
reference waveform using an existing
name.
Manual or Automatic Surge test.
Invalid DA start time
User entered an invalid value.
Test Config
Invalid PI start time
User entered an invalid value.
Test Config
Invalid IR stop time
User entered an invalid value.
Test Config
Invalid DA stop time
User entered an invalid value.
Test Config
Invalid PI stop time
User entered an invalid value.
Test Config
Invalid hipot duration
User entered an invalid value.
Test Config
Invalid step duration
User entered an invalid value.
Test Config
Invalid value
User entered an invalid value.
Test Config
Value cannot be negative
User entered a negative value.
Test Config
Test is disabled in active test config
User tried to run a Sequence, but RLC
and/or Surge test are disabled in the
active test configuration.
Sequenced testing.
www.megger.com
Megger Baker ADX User Guide
145
Error and Failure Messages List
Содержание ADX15
Страница 1: ...Megger Baker ADX Automated Diagnostic Test Equipment User Guide...
Страница 2: ...www megger com Megger Baker ADX User Guide...
Страница 10: ...www megger com Megger Baker ADX User Guide viii Table of Contents...
Страница 44: ...www megger com Megger Baker ADX User Guide 34...
Страница 84: ...www megger com Megger Baker ADX User Guide 74 Routes...
Страница 148: ...www megger com Megger Baker ADX User Guide 138...
Страница 172: ...www megger com Megger Baker ADX User Guide 162...