ME6 IR Dome Configuration Guide
78
Configuring Input Alarms and Output Switches
5 (Optional) You can automatically activate the switch after the alarm is triggered.
a In the
Triggered Action
section, select the
Enable alarm output
check box.
b Select the default switch status from the list.
Select
High
if the default switch status is a closed circuit or select
Low
if the
default switch status is an open circuit.
6 (Optional) You can automatically enable or disable the IR cut filter after the alarm is
triggered.
Note:
This option can be selected only if the
IR Function
option is not configured in
automatic mode (see“Configuring the Camera’s Sensor” on page 59).
a In the
Triggered Action
section, select the
IR cut filter
check box.
b Select the default filter status from the list.
Select
On
if the filter is active (the filter is removed after an alarm) or
Off
if the
filter is not active (the filter is applied after an alarm).
7 Click
Save
to save and apply changes.