Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
59
8.6.3
Module 7 – Code reconstruction technology
PROFINET-IO module identifier
Module ID: 1007
Submodule ID: 1
Description
Module for supporting the code reconstruction technology
Parameter
Tab. 8.5:
Parameters for module 7
Parameter
Description
Addr
.
Data type
Value
range
Default
Maximum width
ratio
The maximum width ratio is used to deter-
mine the light zones. The light zones iden-
tify the beginning or end of patterns.
0
UNSIGNED8
0 … 255
13
Minimum num-
ber of elements
A pattern must have at least this minimum
number of duo-elements, i.e. no patterns
which have fewer duo-elements.
1 …
2
UN-
SIGNED16
2 … 400
6
Code fragment
mode
This parameter can be used to switch CRT
mode on and off.
3.0
Bit
0:
Switched
off
1:
Switched
on
1
Processing end
at end of label
If this parameter is set, a decoded bar
code is only completely decoded after the
scanning beam has exited the entire bar
code.
3.2
Bit
0:
Switched
off
1:
Switched
on
0
Parameter length
4 bytes
Input data
None
Output data
None
NOTICE
Processing end at end of label
If this parameter is set, a decoded bar code is only completely decoded after the scanning beam
has exited the entire bar code. This mode is useful if the quality of the bar code is to be as-
sessed, since more scans are now available for the quality evaluation of the bar code.
This parameter should be set if the AutoControl function is activated (see chapter 8.15.3 "Mod-
ule 92 – AutoControl"). If the parameter is not set, the bar code is immediately decoded and pro-
cessed further as soon as all necessary bar code elements are available