Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
102
8.15
Special functions
8.15.1 Module 90 – Status and control
PROFINET-IO module identifier
Module ID: 1090
Submodule ID: 1
Description
This module supplies various BCL 248i status information to the PROFINET-IO master. Various functions
of the BCL 248i can be controlled via the master's output data.
Parameter
None
Input data
Tab. 8.47:
Input data for module 90
Input data
Description
Addr. Data
type
Value range
Initial
value
Reserved
Free
0.0
Bit
AutoReflAct
state
Signal state of the
AutoReflAct
module
0.1
Bit
0: Reflector is recog-
nized
1: Reflector is hidden
1
AutoControl re-
sult
Indicates whether the result of the
AutoControl
function was a suc-
cessful or unsuccessful reading.
0.2
Bit
0: Quality good
1: Quality bad
0
Reserved
Free
0.3
Bit
RefCode com-
parison state 1
The signal indicates whether the
decoded bar code corresponds to
the reference code with regard to
the comparison criteria as defined
in the comparison function 1. If it
matches, the value 1 is output.
0.4 …
0.5
Bit
0: Not equal
1: Equal
2: Unknown
2
RefCode com-
parison state 2
The signal indicates whether the
decoded bar code corresponds to
the reference code with regard to
the comparison criteria as defined
in the comparison function 2. If it
matches, the value 1 is output.
0.6 …
0.7
Bit
0: Not equal
1: Equal
2: Unknown
2
Input data length:
1 byte
Output data
None
8.15.2 Module 91 – AutoReflAct (automatic reflector activation)
PROFINET-IO module identifier
Module ID: 1091
Submodule ID: 1
Description
The module defines the mode of operation of the diffuse laser sensor for controlling the reading gate.