Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
91
8.12.6 Module 71 – Switching output SWO2
PROFINET-IO module identifier
Module ID: 1071
Submodule ID: 1
NOTICE
Module 71 functions only as a switching output.
Parameter
Tab. 8.41:
Parameters for module 71
Parameter
Description
Addr. Data type
Value range
Default
Bias level
The parameter defines the bias level
of the switching output and, thus, si-
multaneously whether the output is
low-active (0) or high-active (1).
0.1
Bit
0: LOW (0 V)
1: HIGH
(+Ub)
0
Reserved
Free
0.2 …
0.7
Start-up delay
With this parameter, the output pulse
may be delayed by a set time period
in ms
1
UN-
SIGNED16
0 … 65535
ms
0 ms
Switch-on time
The parameter defines the switch-on
time period for the switching output
in ms. If the value is 0, the signal is
static.
3
UN-
SIGNED16
0 … 1300 ms 400 ms
Switch-on func-
tion 1
This parameter specifies an event
which can set the switching output.
5
UNSIGNED8 see chapter
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"
5
Switch-on func-
tion 2
This parameter specifies an event
which can set the switching output.
Switch-on function 1 and switch-on
function 2 are OR linked.
6
UNSIGNED8 see chapter
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"
0
Switch-off func-
tion 1
This parameter specifies an event
which can reset the switching output.
7
UNSIGNED8 see chapter
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"
1
Switch-off func-
tion 2
This parameter specifies an event
which can reset the switching output.
Switch-off function 1 and switch-off
function 2 are OR linked.
8
UNSIGNED8 see chapter
8.12.3
"Switch-on
and switch-
off functions
for operation
as an output"
0