Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
64
8.7.4
Module 13 – Fragmented read result
PROFINET-IO module identifier
Module ID: 1013
Submodule ID: 1
Description
The module defines the transfer of fragmented reading results. To occupy few I/O data, the read results
may be split into several fragments with this module. The fragments can then be transmitted one after an-
other with a handshake.
Parameter
Tab. 8.11:
Parameters for module 13
Parameter
Description
Addr.
Data type
Value
range
Default
Fragment length The parameter defines the maximum length
of the bar code information per fragment.
0
UN-
SIGNED8
1 … 128 0
Parameter length
1 byte
Input data
Tab. 8.12:
Input data for module 13
Input data
Description
Addr.
Data type
Value
range
Initial
value
Fragment num-
ber
Current fragment number
0.0 … 0.
3
BitArea
0 … 15
0
Remaining frag-
ments
Number of fragments which still have to be
read for a complete result.
0.4 … 0.
7
BitArea
0 … 15
0
Fragment size
Fragment length, always corresponds to the
configured fragment length, except for the
last fragment.
1
UN-
SIGNED8
0 … 128 0
Input data length
2 byte consistent
Output data
None
8.7.5
Module 14 – Interlinked read result
PROFINET-IO module identifier
Module ID: 1014
Submodule ID: 1
Description
This module is used to switch to a mode in which all decoding results within one reading gate are combined
into a single read result.