54
Module
Description
Module
identifier
Submod-
ule iden-
tifier
Parame-
ter
Output
data
Input
data
Decoding result 7 Bar code information
28 bytes max.
1027
1
0
30
0
Decoding result 8 Bar code information
64 bytes max.
1028
1
0
66
0
Decoding result 9 Bar code information
128 bytes max.
1029
1
0
130
0
Data formatting
Specification for formatting
the data output
1030
1
23
0
0
Reading gate
number
Number of the reading gate
since system start-up
1031
1
0
2
0
Reading gate
time
Time between opening and
closing
1032
1
0
2
0
Code position
Relative position of the bar
code label in the scanning
beam
1033
1
0
2
0
Reading reliabil-
ity
Calculated reading reliability
for the transmitted bar code
1034
1
0
2
0
Scans per bar
code
Number of scans between
the first and the last time of
detecting the bar code
1035
1
0
2
0
Scans with infor-
mation
Number of scans with pro-
cessed information
1036
1
0
2
0
Decoding quality
Quality of the read result
1037
1
0
1
0
Code direction
Orientation of the bar code
1038
1
0
1
0
Number of digits
Number of digits in the bar
code
1039
1
0
1
0
Code type
Bar code type
1040
1
0
1
0
Data Processing
Characteristics
filter
Configuration of the charac-
teristics filter
1050
1
Data filtering
Configuration of data filtering 1051
1
60
0
0
Segmentation
acc. to the EAN
process
Activation and configuration
of the segmentation acc. to
the EAN process
1052
1
27
0
0
Segmentation via
fixed positions
Activation and configuration
of the segmentation via fixed
positions
1053
1
37
0
0
Segmentation
acc. to identifier
and separator
Activation and configuration
of the segmentation acc. to
identifier and separator
1054
1
29
0
0
String handling
parameter
Definition of placeholder
characters for bar code seg-
mentation, filtering, comple-
tion and reference code pro-
cessing
1055
1
3
0
0