Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
80
Parameter
Description
Addr. Data type
Value range
Default
Start position of
the 1st data
value
Specifies the position of the first
character of the first data value in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
28
UNSIGNED8 0 … 127
0
Start position of
the 2nd identi-
fier
Specifies the position of the first
character of the second identifier
in the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
29
UNSIGNED8 0 … 127
0
Start position of
the 2nd data
value
Specifies the position of the first
character of the second data
value in the data string of the bar
code. The first character in the bar
code has position 1. If the param-
eter is = 0, it is deactivated.
30
UNSIGNED8 0 … 127
0
Start position of
the 3rd identifier
Specifies the position of the first
character of the third identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
31
UNSIGNED8 0 … 127
0
Start position of
the 3rd data
value
Specifies the position of the first
character of the third data value in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
32
UNSIGNED8 0 … 127
0
Start position of
the 4th identifier
Specifies the position of the first
character of the fourth identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
33
UNSIGNED8 0 … 127
0
Start position of
the 4th data
value
Specifies the position of the first
character of the fourth data value
in the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
34
UNSIGNED8 0 … 127
0
Start position of
the 5th identifier
Specifies the position of the first
character of the fifth identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
35
UNSIGNED8 0 … 127
0
Start position of
the 5th data
value
Specifies the position of the first
character of the fifth data value in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
36
UNSIGNED8 0 … 127
0