Online commands
Leuze electronic GmbH + Co. KG
BCL 248i
113
autoConfig
Command
’CA’
Description
Activates or deactivates the
autoConfig
function. Certain label reading parameters
are programmed automatically in the setup by the labels which the bar code reader
reads while the
autoConfig
function is active.
Parameter
'+'
'/'
'-'
Activates
autoConfig
Rejects the last code read
Deactivates
autoConfig
and stores the decoded data in the current
parameter set
Acknowledgment
’CSx’
x
Status
’0’
Valid
’CA’
command
’1’
Invalid command
’2’
autoConfig could not be activated
’3’
autoConfig could not be deactivated
’4’
Result could not be deleted
Response
’xx yyyy zzzzzz’
xx
Number of digits of the read code
yy
Code type of the read code
’01’
2/5 Interleaved
’02’
Code 39
’03’
Code 32
’06’
UPC (A, E)
’07’
EAN
’08’
Code 128, EAN 128
’10’
EAN Addendum
’11’
Codabar
’12’
Code 93
’13’
GS1 DataBar OMNIDIRECTIONAL
’14’
GS1 DataBar LIMITED
’15’
GS1 DataBar EXPANDED
zzzzzz
Contents of the decoded label. A ↑ appears if the label was not cor-
rectly read.