Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
92
Parameter
Description
Addr. Data type
Value range
Default
Comparative
value (event
counter)
If the number of activation events of
the selected switch-on function
reaches this comparative value, the
switching output is activated. A de-
activation event of the selected
switch-off function resets the
counter.
9
UN-
SIGNED16
0 … 65535
0
Comparison
mode (Event
Counter)
Specifies whether the switching out-
put switches only on parity (once) or
also in the event of greater or equal
to (multiple times) after the compara-
tive value is reached.
11
UNSIGNED8 0: SWO
switches
once
1: SWO
switches sev-
eral times
0
Reset mode
(Event Counter)
Specifies whether the counter (Event
Counter) is reset only by the reset bit
and the selected switch-off function,
or if the counter should be automati-
cally reset after the comparative
value is reached.
12
UNSIGNED8 0: Reset bit
and switch-
off function
1: Compara-
tive value
reached
0
Parameter length
23 bytes
Input data
None
Output data
None
Comment
The bias level also defines whether the output is low-active (0) or high-active (1).
Switching on an I/O configured as an output means switching to the active state; switching off, on the other
hand, results in switching to the inactive or idle state.
8.12.7 Module 74 – SWIO status and control
PROFINET-IO module identifier
Module ID: 1074
Submodule ID: 1
Description
Module for handling switching input and switching output signals.
Parameter
None
Input data
Tab. 8.42:
Input data for module 74
Input data
Description
Addr. Data type
Value range
Initial
value
State 1
Signal state of the switching in-
put 1
0.0
Bit
0, 1
0
State 2
Signal state of the switching out-
put 2
0.1
Bit
0, 1
0