Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
106
Slave status
For each slave participant, one bit signals the network status of the respective slave.
• Value = 0: status "not ready"
• Value = 1: status "ready"
Input data length
1 byte
Output data
None
NOTICE
The presence of this module activates the multiScan master mode and sets all necessary mas-
ter communication parameters. In this case, the master IP address corresponds to the
PROFINET-IO device, i.e., its own IP address.
Data format of the IP_ADDRESS
The IP address is entered as a string in the usual IP-V4 notation, e.g., 192.168.0.1. In addition, it is permis-
sible to enter a 0 for the default setting.
IP_ADDRESS = 0 means that the node is deactivated, i.e., the entry is ignored. The slave enable parame-
ter is automatically set according to the IP address setting during the PNIO configuration phase.
8.15.5 Module 101 – multiScan slave addresses 1
PROFINET-IO module identifier
Module ID: 1101
Submodule ID: 1
Description
Additional module for the configuration of the slave addresses for slaves 11-20.
Parameter
Tab. 8.53:
Parameters for module 101
Parameter
Description
Addr. Data type
Value range
Default
multiScan slave
node 11
IP address node 11
0
IP_ADDRESS
0.0.0.0
multiScan slave
node 12
IP address node 12
15
IP_ADDRESS
0.0.0.0
multiScan slave
node 13
IP address node 13
30
IP_ADDRESS
0.0.0.0
multiScan slave
node 14
IP address node 14
45
IP_ADDRESS
0.0.0.0
multiScan slave
node 15
IP address node 15
60
IP_ADDRESS
0.0.0.0
multiScan slave
node 16
IP address node 16
75
IP_ADDRESS
0.0.0.0
multiScan slave
node 17
IP address node 17
90
IP_ADDRESS
0.0.0.0
multiScan slave
node 18
IP address node 18
105
IP_ADDRESS
0.0.0.0
multiScan slave
node 19
IP address node 19
120
IP_ADDRESS
0.0.0.0