Fast commissioning
Leuze electronic GmbH + Co. KG
BCL 248i
15
Fig. 3.4:
MAC address – IP address – individual device name
3.4.7
Check device name
Ä
After completing the configuration phase, recheck the "device names" that have been assigned. Ensure
that these are unique and that all participants are located in the same subnet.
3.5
Further settings
Carry out further settings, such as the control of the decoding and processing of the read data and the con-
figuration of the connected switching inputs and outputs.
Decoding and processing the read data
Ä
Define at least one code type with the desired settings.
In the webConfig tool:
Configuration > Decoder
Control of the decoding
Configure the connected switching inputs according to your requirements.
Ä
First set the I/O mode to input.
Ä
Then configure the switching behavior.
In the webConfig tool:
Configuration > Device > Switching inputs/outputs
Control of the switching outputs
Configure the connected switching outputs according to your requirements.
Ä
First set the I/O mode to output.
Ä
Then configure the switching behavior.
In the webConfig tool:
Configuration > Device > Switching inputs/outputs
Carry out further settings via the PROFINET-IO Controller, such as the control of the decoding and pro-
cessing of the read data and the configuration of the connected switching inputs and outputs, using the pa-
rameters provided by the GSD file.
Ä
Activate the desired modules (at least module 10 and one of the modules 21 … 29).