Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
101
Parameter
Parameter
Description
Addr. Data type
Value range
Default
Code type com-
parison pattern 1
Specifies the type of the ref-
erence bar code.
0
UNSIGNED8 0: No code
1: 2/5 Interleaved
2: Code39
3: Code32
6: UPC, UPCE
7: EAN8, EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: GS1 DataBar
Omnidirectional
14: GS1 DataBar
Limited
15: GS1 DataBar
Omnidirectional Ex-
panded
0
Comparison pat-
tern 1
Parameter string describing
the content of the reference
bar code.
Note: You can also use the
two placeholder characters
that are stored in the "Wild-
card character" and "Don't
care character" parameters.
If the string is empty, no
comparison takes place. If
the most recently stored
character is the wildcard
character, the comparison is
only carried out up to the
character before this wild-
card character. In this way it
is possible to switch off a
comparison according to bar
code length.
1
STRING
30 characters
null termi-
nated
1 … 30 bytes of
ASCII characters
\00
Parameter length
31 bytes
Input data
None
Output data
None
NOTICE
The defined comparison pattern affects both reference code comparators (module 81 – refer-
ence code comparator 1 and module 82 – reference code comparator 2).
ASCII characters that cannot be displayed (<0x20h) must not be used in the comparison pat-
tern.