Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
83
NOTICE
ASCII characters that cannot be displayed (<0x20h) must not be used in the identifier strings.
8.10.4 Module 55 – String handling parameters
PROFINET-IO module identifier
Module ID: 1055
Submodule ID: 1
Description
This module is used to configure placeholder characters for the bar code segmentation, filtering, termina-
tion, and reference code processing.
Parameter
Tab. 8.32:
Parameters for module 55
Parameter
Description
Addr. Data
type
Value
range
Default
Wildcard char-
acter
This parameter is similar to the "don't care
character" parameter. The difference be-
tween this and the "don't care character" is
that all subsequent characters, and not only
one character at a certain position, are disre-
garded until a character pattern is found in
the string that follows the wildcard character
pattern. This character has the same behav-
ior as the wildcard character for the DIR com-
mand in the command line interpreter under
Windows.
0
UN-
SIGNED8
32 … 126 '*'
Don't care char-
acter
Placeholder character. Characters at the po-
sition of the placeholder character are not
taken into account in a comparison. This per-
mits certain areas to be masked.
1
UN-
SIGNED8
32 … 126 '?'
Delete charac-
ter
Delete character for bar code and identifier fil-
tering (characters at the position of the delete
character are deleted in a comparison. This
permits certain areas to be deleted).
2
UN-
SIGNED8
32 … 126 'x'
Parameter length
3 bytes
Input data
None
Output data
None
8.11
Device functions
8.11.1 Module 60 – Device status
PROFINET-IO module identifier
Module ID: 1060
Submodule ID: 1