Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
79
8.10.2 Module 53 – Segmentation via fixed positions
PROFINET-IO module identifier
Module ID: 1053
Submodule ID: 1
Description
The module activates the segmentation via fixed positions. The parameters specify the identifiers to be
searched for, the output mode, and the positions.
Parameter
Tab. 8.30:
Parameters for module 53
Parameter
Description
Addr. Data type
Value range
Default
Identifier list
Identifier 1
The identifier string is used for the
identifier list and the filtering ac-
cording to the segmentation.
0
STRING
5 characters
null termi-
nated
1 … 5 bytes of
ASCII characters
'*'
Identifier 2
See identifier 1
5
STRING
5 characters
null termi-
nated
1 … 5 bytes of
ASCII characters
\0
Identifier 3
See identifier 1
10
STRING
5 characters
null termi-
nated
1 … 5 bytes of
ASCII characters
\0
Identifier 4
See identifier 1
15
STRING
5 characters
null termi-
nated
1 … 5 bytes of
ASCII characters
\0
Identifier 5
See identifier 1
20
STRING
5 characters
null termi-
nated
1 … 5 bytes of
ASCII characters
\0
Identifier output
Output with
identifier
If this switch is not set, the output
of the identifiers is suppressed.
Only the data values that belong
to the identifiers are displayed in
this case.
25.0
Bit
0: Output of the
identifiers is sup-
pressed.
1: Identifiers are
output.
1
Output delimiter This delimiter, if not equal to 0, is
inserted between the identifier
and the associated data value in
the output.
26
UNSIGNED8 0 … 127
0
Fixed positions
Start position of
the 1st identifier
Specifies the position of the first
character of the first identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
27
UNSIGNED8 0 … 127
0