Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
58
Parameter
Tab. 8.4:
Parameters for module 5
Parameter
Description
Addr
.
Data type
Value range
Default
Maximum width de-
viation
Max. permitted width deviation
of a character in percent of the
directly adjacent character
0
UN-
SIGNED8
0 … 100%
15 %
Code 39 max. ele-
ment ratio
Permissible ratio between maxi-
mum and minimum element of
Code 39.
1
UN-
SIGNED8
0 … 255
8
Code 39 character
gap
Permissible ratio for the gap be-
tween two characters for
Code 39.
2
UN-
SIGNED8
0 … 255
3
Codabar max. ele-
ment ratio
Permissible ratio between maxi-
mum and minimum element of
the Codabar code.
3
UN-
SIGNED8
0 … 255
8
Codabar character
gap
Permissible ratio for the gap be-
tween two characters for the
Codabar code.
4
UN-
SIGNED8
0 … 255
3
Codabar Monarch
Mode
The decoding of a Monarch bar
code as Codabar bar code can
be switched on or off.
5.0
Bit
0: Off
1: On
0
Codabar start/stop
character
Switches the transmission of a
start and stop character for the
Codabar code on and off.
5.1
Bit
0: Off
1: On
0
UPC-E extension
Switches the extension of a
UPC-E code to a UPC-A result
on and off.
5.4
Bit
0: Off
1: On
0
Code 128: activate
EAN header
Switches the output of the EAN
header on and off.
5.5
Bit
0: Off
1: On
1
Code 39 conversion
Defines the conversion method
used for Code 39.
5.6
… 5.
7
BitArea
0: Standard (usual
conversion
method)
1: Standard ASCII
(combination of
standard method
and ASCII
method)
2: ASCII (This
conversion
method uses the
entire ASCII char-
acter set)
0
Parameter length
6 bytes
Input data
None
Output data
None