Online commands
Leuze electronic GmbH + Co. KG
BCL 248i
122
Command
’PD’
Acknowledgment
positive
PT<BCC><PS-Type><Status><Address><Parameter Value Address><Parameter
Value 1>… [;<Address><Parameter Value Address>]
<BCC>
Check-digit function during transmission, unit [dimensionless]
’0’
No check digits
’3’
BCC mode 3
<PS type>
Memory from which the values are to be read, unit [dimensionless]
’0’
Values stored in flash memory
’3’
Operating values stored in RAM
<Status>
Mode of parameter processing, unit [dimensionless]
’0’
No further parameters
’1’
Additional parameters follow
<Ad-
dress>’aaaa’
Relative address of the data within the data set, four-digit, unit [dimen-
sionless]
<P.value>
Parameter value of the parameter stored at this address. The 'bb' pa-
rameter set data is converted for transmission from HEX format to a 2-
byte-ASCII format.
Acknowledgment
negative
’PS=<aa>’
Parameter reply:
<aa>
Status acknowledgment, unit [dimensionless]
’0’
No difference
’1’
Syntax error
’2’
Impermissible command length
’6’
Impermissible combination, parameter set 1 and parameter set
2
’8’
Invalid parameter set
Writing parameter set
Command
’PT’
Description
The parameters of the bar code reader are grouped together in a parameter set and
permanently stored in memory. There is one parameter set in permanent memory and
one operating parameter set in volatile memory; in addition, there is a default parame-
ter set (factory parameter set) for initialization. This command can be used to edit the
first two parameter sets (in permanent and volatile memory). A check sum can be
used for reliable parameter transfer.