Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
89
8.12.3 Switch-on and switch-off functions for operation as an output
The following options are available for switch-on and switch-off functions in the "output" operating mode:
Tab. 8.38:
Switch-on/switch-off functions
Name
Value Comment
No function
0
No functionality
Reading gate start
1
Reading gate end
2
Positive reference code comparison 1
3
Negative reference code comparison 1 4
Valid read result
5
Invalid read result
6
Device ready
7
The device is in a ready state.
Device not ready
8
The device is not yet ready (motor and laser are being acti-
vated).
Data transmission active
9
Data transmission not active
10
AutoControl good quality
13
AutoControl bad quality
14
Reflector detected
15
Reflector not detected
16
External event, pos. edge
17
In the PROFINET case, the external event is generated
with the aid of module 74 – "I/O status and control", see
chapter 8.12.7 "Module 74 – SWIO status and control".
External event, neg. edge
18
See above
Device active
19
Decoding is currently being performed.
Device in standby mode
20
Motor and laser inactive.
No device error
21
An error was detected.
Device error
22
Device is in an error state.
Positive reference code comparison 2
23
Negative reference code comparison 2 24
8.12.4 Input functions for operation as an input
Tab. 8.39:
Input functions
Name
Value
Comment
No function
0
No functionality
Reading gate activation
1
Reading gate deactivation only
2
Reading gate activation only
3
Reference bar code teach-in
4
Start/stop AutoConfiguration mode
5