Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
86
Input data length:
1 byte
Output data
Tab. 8.37:
Output data for module 63
Output data
Description
Addr. Data type
Value range
Initial
value
Alignment mode Signal activates and deactivates the
alignment mode for optimum align-
ment of the BCL 248i with the bar
code.
0.0
Bit
0 > 1: On
1 > 0: Off
0
Output data length:
1 byte
8.12
Switching inputs/outputs SWIO 1/2
These modules define the mode of operation of the two digital switching inputs and outputs (I/Os). They are
separated into individual modules for configuring the individual I/Os and a shared module for signaling the
status and controlling all I/Os.
8.12.1 Parameters for operating as an output
Start-up delay
With this setting, the output pulse can be delayed by the specified time (in ms).
Switch-on time
Defines the switch-on time period for the switching input. Any activated switch-off function then no longer
has any function.
A value of 0 causes the output to be set statically; this means that the selected input function(s) activates
the output, and the selected switch-off function(s) deactivates it again.
1
2
3
4
1
Switch-on signal
4
Start-up delay
2
Switch-off signal
3
Output
Fig. 8.5:
Example 1: Start-up delay > 0 and switch-on time = 0