Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
70
NOTICE
The text for erroneous readings does not permit the use of ASCII characters that cannot be dis-
played (<0x20h).
8.8.4
Module 31 – Reading gate number
PROFINET-IO module identifier
Module ID: 1031
Submodule ID: 1
Description
The module defines input data for the communication of the number of reading gates since system start.
Parameter
None
Input data
Tab. 8.17:
Input data for module 31
Input data
Description
Addr. Data type
Value
range
Initial
value
Reading gate
number
The BCL 248i transmits the current read-
ing gate number. The reading gate num-
ber is initialized with the system start and
is then incremented continuously. At
65535, an overflow occurs and the
counter starts again from 0.
0 … 1 UN-
SIGNED16
0 … 6553
5
0
Input data length
2 byte consistent
Output data
None
8.8.5
Module 32 – Reading gate time
PROFINET-IO module identifier
Module ID: 1032
Submodule ID: 1
Description
This module returns the time between opening and closing of the last reading gate.
Parameter
None
Input data
Tab. 8.18:
Input data for module 32
Input data
Description
Addr. Data type
Value range
Initial
value
Opening dura-
tion of the read-
ing gate
Opening duration of the last
reading gate in ms.
0 … 1 UN-
SIGNED16
0 … 65535 ms
If the range is ex-
ceeded, the value re-
mains at 65535
0 ms