Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
73
8.8.10 Module 37 – Decoding quality
PROFINET-IO module identifier
Module ID: 1037
Submodule ID: 1
Description
The module defines input data for the communication of the calculated decoding quality of the currently
transmitted bar code.
Parameter
None
Input data
Tab. 8.23:
Input data for module 37
Input data
Description
Addr. Data type
Value range
Initial
value
Decoding quality
Decoding quality of the transmitted
bar code in %.
0
UNSIGNED8 0 … 100%
0 %
Input data length
1 byte consistent
Output data
None
8.8.11 Module 38 – Code direction
PROFINET-IO module identifier
Module ID: 1038
Submodule ID: 1
Description
The module defines input data for the communication of the detected code direction of the currently trans-
mitted bar code.
Parameter
None
Input data
Tab. 8.24:
Input data for module 38
Input data
Description
Addr. Data type
Value range
Initial
value
Code direction
Code direction of the transmitted bar
code
0
UNSIGNED8 0: Normal
1: Inverted
2: Unknown
0
Input data length
1 byte
Output data
None